![Motorline professional MC15BA Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/motorline-professional/mc15ba/mc15ba_userand-installers-manual_1838623006.webp)
5A
5B
EN
EN
03. CONFIGURATION
03. CONFIGURATION
MAIN MENU
• PGM. AUT. |
AUTOMATIC COURSE SCHEDULE
• ACCESS TO EXTENDED MENU 1
• T. PAUSA |
PAUSE TIME PROGRAMMING FOR AUTOMATIC CLOSURE (4MIN MAX)
With the limit switches already set, the control board allows a automatic programming
of the working course (recommended).
01. Unlock the barrier, put the rod halfway, and lock the barrier.
02. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the
times necessary until the
LED PGM AUT starts to flash.
03. Press the SET button and hold and the rod have to start closing!
04. Let the rod close, open and re-close without releasing the SET button!
05. By closing the second time, the LED AUTO PGM will remain lit and the T. PAUSE LED
will begin to flash. Release the
SET button and wait 10 seconds until the T. PAUSE LED
stops flashing.
The control board automatically sets a deceleration time during the opening and the
closure equal to 15% of the full course.
The control board is supplied by the manufacturer with automatic closure active after
10sec.
Disable the automatic closure:
01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the
times necessary until the
LED T. PAUSA starts to flash.
02. Press the SET button twice in 2sec! The T.PAUSA LED turns off and the function is
disabled.
EXTENDED MENU 1
To access the Extended Menu 1 options follow these instructions:
01. Press and hold the SET button for 5 seconds, the LEDs T.MOT.PED and T.PAUSA will
flash alternately.
02. The control board provides 30 seconds to select functions form the extended menu 1
(using the
SEL and SET buttons), and after this time it returns to the main menu.
EXTENDED MENU 1
LED
LED OFF
LED ON
•
CODE
Step by step
Inverter
•
CODE PED.
Lightbulb
Pré-lightbulb
•
IN.CMD.AP
Not used
•
L. CORT.
Not used
•
PGM. AUT.
Follow Me = OFF
Follow Me = ON
•
T. MOT.
Not used
•
T. MOT. PED
Switched Flashing Light ON/OFF
•
T. PAUSA
Switched Flashing Light ON/OFF
02. Press SET button once to change the operating mode.
The
L.CORT LED will turn on/ turn off e a configuration is complete.
Door Lock Mode (LED ON): with the barrier closed, the control board continuously feed
the magnetic lock until 1 second before iniciate any opening operation.
The output is fed back 1 second before it closes completely, so that once the maneuver
ends, the rod remains attached to the lock.
Lightbulb Mode (LED OFF): the control board provides power to the lightbulb during the
closing and opening phase, turning it off when the barrier is open or closed.
Activate or change the pause time for automatic closure:
01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the
times necessary until the
LED T. PAUSA starts to flash.
02. Press once the SET button, wait the desired time for the pause time
and press again the
SET button (the expected time is defined as the pause time).
The
T.PAUSA LED remains lit and the pause time is active.
Operation in Automatic Mode (CODE LED ON):
• The first impulse from the transmitter/ push button triggers the barrier’s opening
during the defined working time.
• The second impulse triggers the barrier closure.
• If you press the transmitter / push-button during opening or closing maneuvers, the
• CODE |
STEP BY STEP / AUTOMATIC OPERATION
If the rod begins to open, release the SET button, invert the cables of the connectors 5
and 7 of the CN2 and 07 and 09 of the CN3, and start this program from the beginning.