4A
4B
EN
EN
03. CONFIGURATION
03. CONFIGURATION
MAIN MENU
LED
LED OFF
LED ON
•
CODE
No code
Inserted code
•
CODE PED.
Not used
•
IN.CMD.AP
Disabled
Enabled
•
L. CORT.
Lightbulb
Magnetic lock
•
PGM. AUT.
Automatic PGM=OFF
Automatic PGM=ON
•
T. MOT
Not used
•
T. MOT. PED
Not used
•
T. PAUSA
Without automatic closure
With automatic closure
The control board only accepts Dip-Switch transmitters or MOTORLINE Rolling Code
transmitters, and it has a maximum capacity of 120 transmitters. When trying to pro-
gram the 121º transmitter, all the programming LEDs will flash simultaneously (me-
mory is full)
To program new commands:
01. Press SEL button once, the CODE LED will begin to flash.
02. Press once the transmitter button you want to program, during 1sec.
03. The LED CODE remains lit permanently, indicating the programming success.
To delete all configured transmitters:
01. Press SEL button once, the CODE LED will begin to flash.
02. Press the SET button once! The CODE LED will turn off and all controls will be
deleted.
With the function ativated, the control board rejects all the transmitter signals during
the opening maneuvers and automatic pause time. Its important that this function is
ativated during a magnetic coil instalation, because the control board will ignore the
crossings performed during the opening course and the pause time.
The control board is supplied by the manufacturer with this funcion active.
Activate (LED ON) / deactivate (LED OFF) function:
01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the
times necessary until the
INB CMD AP LED starts to flash.
02. Press SET button once to enable / disable the function. The INB CMD AP LED ON
indicates that the function is active and the
LED OFF indicates that the function is
deativated.
• CODE |
PROGRAMMING TRANSMITTERS
• INB. CMD. AP |
TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME
• OBSTACLES DETECTION
The control board has a VR2 trimmer, controlled by microprocessor, for
regulating the opposition force required for the detection of obstacles.
The adjustment can be performed with a intervention time between 0.1
seconds and 3 seconds.
NOTA: Setting the VR2 trimmer to its minimum, disables the obstacles
detection functionality.
SENS.
+
-
• In the presence of limit-switch devices connected to the control board, the detetion
of obstacles causes the complete inversion of the movement during the closure and
the inversion for only 2 seconds during the opening course.
• When there are limit-switch devices connected to the control board, the detetion of
obstacles causes always the inversion of the movement during the closure except in
last 5 seconds of the maneuver for which it performs the stop.
During the opening, it inverts the movement by only 2 seconds, except in the last 5
seconds of maneuver (stoping the motors).
• L. CORT |
LIGHBULB AND MAGNETIC LOCK SELECTION
The control board has a 110V or 230V AC output for a lightbulb or a magnetic lock co-
nection (applied in the rod tip).
The control board is supplied by the manufacturer with this funcion active (LED ON).
To change the operating mode, follow these steps:
01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the
times necessary until the
LED L. CORT starts to flash.
PROGRAMMING PRE-RECOMENDATIONS
MAIN MENU
MAIN MENU