03. CONFIGURATION

03. CONFIGURATION

MAIN MENU

LED

LED OFF

LED ON

• 

CODE

No code

Inserted code

• 

CODE PED.

Not used

• 

IN.CMD.AP

Disabled

Enabled

• 

L. CORT.

Lightbulb

Magnetic lock

• 

PGM. AUT.

Automatic PGM=OFF

Automatic PGM=ON

• 

T. MOT

Not used

• 

T. MOT. PED

Not used

• 

T. PAUSA

Without automatic closure

With automatic closure

The control board only accepts Dip-Switch transmitters or MOTORLINE Rolling Code 

transmitters, and it has a maximum capacity of 120 transmitters. When trying to pro-

gram the  121º  transmitter, all the programming LEDs will flash simultaneously (me-

mory is full)

To program new commands:

01. Press SEL button once, the CODE LED will begin to flash.

02. Press once the transmitter button you want to program, during 1sec.

03. The LED CODE remains lit permanently, indicating the programming success.

To delete all configured transmitters:

01. Press SEL button once, the CODE LED will begin to flash.

02. Press the SET button once! The CODE LED will turn off and all controls will be

deleted.

With the function ativated, the control board rejects all the transmitter signals during 

the opening maneuvers and automatic pause time. Its important that this function is 

ativated during a magnetic coil instalation, because the control board will ignore the 

crossings performed during the opening course and the pause time. 

The control board is supplied by the manufacturer with this funcion active.

Activate (LED ON) / deactivate (LED OFF) function:

01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the 

times necessary until the 

INB CMD AP LED starts to flash.

02. Press SET button once to enable / disable the function. The INB CMD AP LED ON 

indicates that the function is active and the 

LED OFF indicates that the function is 

deativated.

• CODE    | 

PROGRAMMING TRANSMITTERS

• INB. CMD. AP    | 

TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME

• OBSTACLES DETECTION 

The control board has a VR2 trimmer, controlled by microprocessor, for 

regulating the opposition force required for the detection of obstacles.

The adjustment can be performed with a intervention time between 0.1 

seconds and 3 seconds.

     

NOTA: Setting the VR2 trimmer to its minimum, disables the obstacles 

detection functionality.

SENS.                           

+

-

• In the presence of limit-switch devices connected to the control board, the detetion 

of obstacles causes the complete inversion  of the movement during the closure and 

the inversion for only 2 seconds during the opening course.

• When there are limit-switch devices connected to the control board, the detetion of 

obstacles causes always the inversion of the movement during the closure except in 

last 5 seconds of the maneuver for which it performs the stop.

During the opening, it inverts the movement by only 2 seconds, except in the last 5 

seconds of maneuver (stoping the motors).

• L. CORT    | 

LIGHBULB AND MAGNETIC LOCK SELECTION

The control board has a 110V or 230V AC output for a lightbulb or a magnetic lock co-

nection (applied in the rod tip).

The control board is supplied by the manufacturer with this funcion active (LED ON).

To change the operating mode, follow these steps:

01. Press SEL button once, the CODE LED will begin to flash. Press the SEL button the 

times necessary until the 

LED L. CORT starts to flash. 

PROGRAMMING PRE-RECOMENDATIONS

MAIN MENU

MAIN MENU

Содержание MC15BA

Страница 1: ...v3 0 REV 12 2016 EN USER INSTALLER MANUAL MC15BA...

Страница 2: ...s attempt to repair or tune the automatism Must call qualified technician only The installer must have certified professional knowledge at the level of mechanical assemblies in doors and gates and con...

Страница 3: ...THE CONTROL BOARD TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS CN1 CN2 04 Locking device NC Closing push button input NO 05 Common GND output 06 Safety device input NC 07 Motor s opening limit s...

Страница 4: ...0 strength In each movement startup the central applies full power for 2 seconds even when it is made the force regulation for avalue than the maximum FORZA Whenever the VR1 trimmer is adjusted the co...

Страница 5: ...ry until the INB CMD AP LED starts to flash 02 Press SET button once to enable disable the function The INB CMD AP LED ON indicates that the function is active and the LED OFF indicates that the funct...

Страница 6: ...and SET buttons and after this time it returns to the main menu EXTENDED MENU 1 LED LED OFF LED ON CODE Step by step Inverter CODE PED Lightbulb Pr lightbulb IN CMD AP Not used L CORT Not used PGM AUT...

Страница 7: ...is deativated PGM AUT FOLLOW ME CODE PED PRE LIGHTBULB ACCESSING THE EXTENDED MENU 2 To access the options from Extended Menu 2 read the following instructions 01 Activate the extended menu 1 see ACC...

Страница 8: ...control board to the factory settings press the SEL and SET keys simultaneously At this time all LEDs will light up simultaneously and then will turn off indicating the reset s sucess 04 COMPONENTS TE...

Страница 9: ...mittent mode indicating the error When the photocells operation is corrected the control board returns to it s normal functioning This action by the control board allows to recognize failures in accor...

Страница 10: ...ge 7B 3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site an...

Страница 11: ...2 3 1 2 3 4 5 V ENC DV NC COM 12 24V DV 12 24V L PE N PUL 24Vac EN 06 CONNECTION SCHEME COMPONENT CONNECTION TO THE CONTROL BOARD Flashing Light Barrier At BL you can connect a STOP switch button Eve...

Страница 12: ...is based on the existing letters of the LED strip It is considered as incorrect posi tion when the letters are inverted with the light sensor on the left L SENSE Only lights up when it detects that th...

Отзывы: