v3.0
REV. 12/2016
EN
USER / INSTALLER MANUAL
MC15BA
Страница 1: ...v3 0 REV 12 2016 EN USER INSTALLER MANUAL MC15BA...
Страница 2: ...s attempt to repair or tune the automatism Must call qualified technician only The installer must have certified professional knowledge at the level of mechanical assemblies in doors and gates and con...
Страница 3: ...THE CONTROL BOARD TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS CN1 CN2 04 Locking device NC Closing push button input NO 05 Common GND output 06 Safety device input NC 07 Motor s opening limit s...
Страница 4: ...0 strength In each movement startup the central applies full power for 2 seconds even when it is made the force regulation for avalue than the maximum FORZA Whenever the VR1 trimmer is adjusted the co...
Страница 5: ...ry until the INB CMD AP LED starts to flash 02 Press SET button once to enable disable the function The INB CMD AP LED ON indicates that the function is active and the LED OFF indicates that the funct...
Страница 6: ...and SET buttons and after this time it returns to the main menu EXTENDED MENU 1 LED LED OFF LED ON CODE Step by step Inverter CODE PED Lightbulb Pr lightbulb IN CMD AP Not used L CORT Not used PGM AUT...
Страница 7: ...is deativated PGM AUT FOLLOW ME CODE PED PRE LIGHTBULB ACCESSING THE EXTENDED MENU 2 To access the options from Extended Menu 2 read the following instructions 01 Activate the extended menu 1 see ACC...
Страница 8: ...control board to the factory settings press the SEL and SET keys simultaneously At this time all LEDs will light up simultaneously and then will turn off indicating the reset s sucess 04 COMPONENTS TE...
Страница 9: ...mittent mode indicating the error When the photocells operation is corrected the control board returns to it s normal functioning This action by the control board allows to recognize failures in accor...
Страница 10: ...ge 7B 3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site an...
Страница 11: ...2 3 1 2 3 4 5 V ENC DV NC COM 12 24V DV 12 24V L PE N PUL 24Vac EN 06 CONNECTION SCHEME COMPONENT CONNECTION TO THE CONTROL BOARD Flashing Light Barrier At BL you can connect a STOP switch button Eve...
Страница 12: ...is based on the existing letters of the LED strip It is considered as incorrect posi tion when the letters are inverted with the light sensor on the left L SENSE Only lights up when it detects that th...