08.B
08.A
CN2
CN1
CN2
CN1
▷ TECHNICAL SPECIFICATIONS (MC65)
CONTROL BOARD CONNECTIONS ◁
▷ Power supply
▷ Motor output
▷ Output courtesy light
▷ Number of
transmitters for memorize
▷ Number of sensors Wireless for memorize
▷ Radio receiver
▷ Compatible transmitters
▷ Working temperature
AC 230V 50/60Hz 1000W máx.
230V~ 500W máx.
230V ~ 500W máx.
5 máx.
1 máx.
433,92 MHz
-20÷55°C
12-18 Bit - Rolling Code
Antenne Mass Input (COM)
Antenne control board pole input
01 ▷ Ground connection input.
02 ▷ Ground connection input.
03 ▷ 230V power supply Input ~ (PHASE)
04 ▷ 230V power supply Input ~ (NEUTRAL)
05 ▷ Rising/Closing motor output
06 ▷ Common motor output
07 ▷ Descent/Opening motor output
08 ▷ 230V presence light output ~ (PHASE)
09 ▷ 230V presence light output ~ (NEUTRAL)
Control board MC65, for awning automation, with possibility to connect a presence light
with timer, with operation via transmitter and Wireless Sensor (sun/wind/rain).
GROUP OR GENERAL CENTRALIZATION ◁
▷ Centralization via radio through transmitter
The centralization of two or more control boards via radio allows simultaneous
movement of ascending or descending of more awnings.
The centralization is performed by entering the same codes (keys) from a transmitter to
all control boards at maximum distance of 20 meters from the transmitter point in, in
order to get the general or partial motion of more automations. For a satisfactory radio
centralization, you must choose carefully the location of installation.
The operating range is not only related with the technical characteristics of the device,
it may vary depending on the radioelectric conditions of the location.
▷ Presence Light operation with remote control
It is also possible to program a remote control channel to turn on or off a 230Vac lamp
at a distance, connected to connectors of the board (8-9) CN1.
Whenever it is made a full opening/closing of the awning, the control board
turns off the presence light.
04
.
MC65 CONTROL BOARD
04
.
MC65 CONTROL BOARD