Turn off the power supply.
With the help of a screwdriver remove the lower screw (Fig.13a).
Remove the cover and the LED strip (Fig.13a).
Disconnect the connector (Fig.13b).
4.9 - Replacement of the leds - 24 Vdc
Connect the new LEDs and insert them into the mask.
Insert the mask first inserting the side of the seal and then securing
it with the screw.
COM
PAR
OPEN
CLOSE
SBS
NEG
PH-POW
PH1
PH2
COM
FLASH
LED
SEN
COM
STOP
EDGE
EDGE
COM
ELEC
COM
IND
POWER SUPPLY
N
T2A
L
230Vac 50/60Hz
PHOTOTEST
LIGHT
TWILIGHT SENSOR
LED OUTPUT
STOP
OPEN
PHOTOCELL 1
PHOTOCELL 2
CLOSE
PARCIAL
STEP BY STEP
+ COMMON
+ COMMON
SAFETY EDGE
ELECTRIC LOCK
NEGATIVE
SBS
M1
M2
BATTERIES (ACCESSORY)
COMMON
FLASH
SHIELD
ANT
PH1
RX
2
1
PH1
TX
SHIELD
ANT
COMMON
FLASH
4.10 - Electrical connections
TRANSFORMER
WARNING - Before making the connections, ensure that the control unit is not powered up.
POWER SUPPLY CONNECTIONS
L
Power supply 230 Vac 50-60 Hz
Earth
N
Power supply neutral 230 Vac 50-60 Hz
M2
M2
M1
M1
Содержание FULL24
Страница 42: ...42 INSTALLER DATA INSTALLER DATA DATE SIGNATURE...
Страница 43: ...43...