model no. 011-2102-0  |  contact us 1-888-942-6686

Reason

Solution

“True RMS”

 voltage meter is required to properly  

measure output voltage of a modified wave inverter.

Test output voltage with a 

“True RMS”

 voltage meter and 

the correct  voltage will be displayed.

TROUBLESHOOTING

PROBLEM: OUTPUT VOLTAGE BELOW 100 V AC

Reason

Solution

Poor contact with battery terminals.

Shut down inverter and disconnect. Clean terminals 
thoroughly and reconnect. 

Blown DC battery fuse(s).

Turn off inverter. Fix problem. Replace fuse(s) with same 
type and rating.

PROBLEM: NO INPUT VOLTAGE

Reason

Solution

Battery voltage below 10 V.

Charge or replace battery.

Inverter is too hot (thermal shutdown mode). Will be

 

indicated on LCD panel.

Allow inverter to cool. Check for adequate ventilation. Re-
duce the load on the inverter to rated continuous power.

Unit may be defective.

See warranty and call customer service.

PROBLEM: INVERTER IS SHUT DOWN

Reason

Solution

Input voltage below 10.5 V.

 

 Will be indicated on LCD 

panel.

Keep input voltage above 10.5 V to maintain 

 

regulation.

Poor or weak battery condition.

Recharge or replace battery.

Inadequate power being delivered to the inverter or 
excessive voltage drop.

Use lower gauge (heavier) cable. Keep cable length as 
short as possible.

PROBLEM: LOW BATTERY ALARM ON ALL THE TIME

Reason

Solution

TV does not turn on.

Contact TV manufacturer to find out if the TV is compatible 
with a modified sine wave.

PROBLEM: TV DOES NOT WORK

Internal fuse(s) may have blown.

Serviceable/replaceable by a qualified Technician. 
Check spec on page 17 for fuse size and type.

Содержание Eliminator 011-2100-4

Страница 1: ...model no 011 2102 0 IMPORTANT Please read this manual carefully before running this power inverter and save it for reference INSTRUCTION MANUAL 4000 W POWER INVERTER ...

Страница 2: ...eted at the DIY customer Our extensive line of engine oils and lubricants antifreeze and coolants washer fluids transmission fluids and treatments winter chemicals garage and car interior accessories batteries chargers and boosters as well as lifting equipment was developed with our roads and drivers in mind With over 600 individual automotive products Eliminator has helped keep Canadians on the g...

Страница 3: ... Gauges Understanding Controls and Features Mounting the Inverter Connecting the Inverter Operation Television and Audio Suggestions Operating a Microwave Oven With Your Power Inverter How This Modified Sine Wave Power Inverter Works Best Use of Battery Power Troubleshooting Specifications Warranty and Returns 4 4 4 4 4 5 5 6 7 8 9 10 11 11 12 13 13 13 14 14 15 15 16 16 17 18 TABLE OF CONTENTS SAV...

Страница 4: ... test All inverters are designed to automatically shut down in the event of a power overload This protection feature prevents damage to the unit while running appliances with combined wattages below the 4000 W power range Turn on the highest wattage appliance first then other appliances If an appliance combination in the 4000 W power range will not operate properly then it is likely that this inve...

Страница 5: ...ve two types of equipment The majority of portable appliances do not have this problem Most portable appliances use separate transformers or chargers that plug into AC receptacles to supply a low voltage DC or AC output to the appliance If the appliance label states that the charger or adaptor produces a low voltage DC or AC output 30 V or less there will be no problem powering that charger or ada...

Страница 6: ...oad Power consumption is rated in watts or it can be calculated from amperes amps This information is usually stamped or printed on most appliances and equipment If this information is not indicated on the appliance or equipment check the owner s manual For electrically sensitive equipment contact the manufacturer to determine if the device you are using is compatible with modified sine wave AC Mu...

Страница 7: ...orts 2 4 A each Allows the user to power simultaneously two 2 4 A compatible devices such as tablets or 1 A compatible devices such as cell phones A B C D E FRONT PANEL 011 2102 0 Main Switch is used for complete shutdown of the inverter MENU Button Pressing the button will change the display between OUTPUT WATTAGE or INPUT VOLTAGE A B C D E ...

Страница 8: ... b Low voltage c Voltage overload Temperature Shutdown 1 2 3 4 3 4 1 2 Remote Instructions The included remote control features an LED indicator showing on off light push button and 20 6 m cable that simply plugs into the inverter Features A LED indicator B Push button Indicator Solid Green Inverter on No Colour Inverter off A B model no 011 2102 0 contact us 1 888 942 6686 ...

Страница 9: ...tant cables rated for damp or wet locations We would strongly recommend having this installed by a certified electrician since these wires will have a live current if installed improperly can be a fire or shock hazard Once installed have the wires come through the front plate by removing the middle circle of the front plate Once all connections are secure and properly installed and the front plate...

Страница 10: ...1 2102 0 contact us 1 888 942 6686 continuation t REAR PANEL 011 2102 0 High Speed Cooling Fans When the temperature inside the inverter exceeds a preset limit the Cooling Fans automatically turn on to cool the inverter When the temperature reduces the fans turn off Positive Power Input Terminal Negative Power Input Terminal Remote Control Receptacle Ground Terminal F G H I J F G H I J ...

Страница 11: ...ne ANL fuse 2 AWG 3 0 9 m included W 200 A inline ANL fuse 0 AWG 3 0 9 m included W 400 A inline ANL fuse 011 2101 2 011 2102 0 CAUTIONS Loose connections can result in a severe decrease in voltage that can cause damage to cables and insulation Failure to make correct polarity pos neg connection between the inverter and the battery bank can result in blowing fuses in the inverter and can permanent...

Страница 12: ...has to provide as above 2 Estimate the number of hours the appliances will be in use between battery recharges This will differ depending on appliances As an example a typical home use coffeemaker draws 500 W during its brew time of 5 minutes it maintains the temperature of the pot at about 100 W Typical use of a microwave oven is only for a few minutes Some longer operating time appliances are la...

Страница 13: ...osion resistant fasteners sized 10 or larger CONNECTING THE INVERTER This inverter has two DC cable connections one positive and one negative The order of steps in the following procedure minimizes the danger of sparking near the battery bank 1 Prepare all cable set ends with ring terminals at the battery ends 2 Install one fuse holder with fuse in the pos cable close to the battery bank end 3 Mak...

Страница 14: ...evision picture may be unavoidable especially in weak signal areas However here are some suggestions that may improve reception 1 First make sure that the television antenna produces a clear signal under normal operating conditions Also ensure that the antenna cable is properly shielded and of good quality 2 Change the positions of the inverter antenna cables and TV power cord 3 Isolate the TV its...

Страница 15: ...ttery to 145 V DC STAGE 2 The inverter then converts the high voltage DC into 120 VAC household current using an advanced MOSFET transistor in a full bridge configuration This design provides this inverter with the capability to start and run difficult reactive loads while providing excellent overload capability The waveform that is generated by this conversion is a modified sine wave as shown in ...

Страница 16: ...oo hot thermal shutdown mode Will be indicated on LCD panel Allow inverter to cool Check for adequate ventilation Re duce the load on the inverter to rated continuous power Unit may be defective See warranty and call customer service PROBLEM INVERTER IS SHUT DOWN Reason Solution Input voltage below 10 5 V Will be indicated on LCD panel Keep input voltage above 10 5 V to maintain regulation Poor or...

Страница 17: ...t 0 9 A DC Optimum Efficiency 85 min Fuse A 150 A 3 Fuse Type Internal Blade Output Wave Form Modified Sine Wave Touch Temperature 65 C 149ºF Max Operating Temperature 20 to 40ºC 4 to 104ºF Operating Storage Humidity RH 5 to 95 Cooling System Thermo Fan THD 40 Dimensions LxWxH 15 3 8 x 7 5 8 x 5 9 16 39 1 x 19 4 x 14 1 cm Assembled Weight 11 lb 8 oz 5 22 kg NOTE All specifications are typical at 1...

Страница 18: ...uction manual for future use Should this product be passed on to a third party this instruction manual must be included The English version of this manual is available online at www canadiantire ca manuals 4010229 This MotoMaster Eliminator product carries a three 3 year warranty against defects in workmanship and materials At its discretion MotoMaster Canada agrees to have any defective part s re...