Carefully remove the end cap from the 12 V plug by rotating counter-clockwise and set the
pieces aside.
Inspect the fuse. The fuse is a cylindrical glass/metal tube.
If the internal metallic filament of the fuse is broken, the fuse must be replaced.
This inflator includes one spare fuse. It can be located on the top panel of the inflator(Part 9).
Insert either end of the spare fuse in to the 12 V plug.
Replace the end cap and metallic tip of the plug and secure by rotating clockwise.
verify your power source is operational and the AC/OFF/DC selector is in the appropriate
setting. If the display does not illuminate, proceed with the following directions:
TROUBLESHOOTING (FUSE REPLACEMENT)
15 A 250 V
2
1
6
4
3
5
If the LCD screen does not illuminate when plugged in to an operational power source,
WARNING:
Read instructions before use.
WARNING:
Allow air compressor to cool for 15 minutes after 10 minutes of continuous operation. Maximum
Duty Cycle: 40% at 35 PSI. Do not touch the metal valve chuck, adaptors, or 12 V plug during or
immediately after use as they may be hot. Allow the unit to cool to room temperature before handling.
RISK OF EXPLOSION:
Do not overinflate objects. Overinflation could cause damage and/or personal injury.
Do not adjust regulator to result in output pressure greater than marked maximum pressure of objects to be
inflated.
WARNING:
This product has more than one connection to electrical sources. To reduce risk of electric shock
or injury, disconnect all electrical connections before servicing. Do not expose to rain, or use in or near
sources of water. For indoor use only.
RISK OF INJURY:
Do not direct air stream at the body. Do not leave inflator unattended when in use.
HOUSEHOLD USE ONLY.
Store indoors and away from water and moisture when not in use.
TROUBLESHOOTING (FUSE REPLACEMENT)
Model no. 009-5206-4 / Contact us 1-888-942-6686