Setting up the UPC
UPC Setup at a Glance
Below is the proper start-up sequence of the UPC. A summary of this procedure is also
indicated on the front panel of the UPC (labeled “STARTUP SEQUENCE”):
1. Confirm all switches are in the OFF position.
2. Connect the charge input power source (48V input socket or 4 V-Mount
batteries on the top lid).
3. Select the appropriate power source with the INPUT SELECT SWITCH, make
sure the voltmeter shows expected voltage.
4. Connect the UPC output cable to the PSU. Make sure the PSU MAIN PWR switch
is in the OFF position.
5. Turn the CHARGE INPUT SWITCH ON.
6. Turn the 48V POWER OUTPUT SWITCH ON to begin charging the
ultra-capacitors. Allow around 4min to charge. Once the READY LED turns
green, Turn ON the PSU MAIN PWR switch. Make sure that the PSU voltmeter
displays 48V and that the COM LED on the UPC turns on.
: Failure to follow these instructions and those below can result in serious
injury, death or damage.
These instructions will be demonstrated in our training videos and found online at
. All terminology is referred to in the above diagrams.
8