background image

WARNING!

DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT
FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND
ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS,
SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR
OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS,
CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER
OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT -
OTHERWISE, INJURY OR DAMAGE MAY OCCUR.

ACCESSORIES WARNING

Invacare products are specifically designed and manufactured for use in
conjunction with Invacare accessories. Accessories designed by other
manufacturers have not been tested by Invacare and are not recommended
for use with Invacare products.

INSTALLATION WARNING

The procedures in this manual should be performed by a qualified technician.
After any adjustments, repair or service and before use, make sure that all
attaching component parts are secure.
DO NOT install the Invacare Matrx Mini assembly onto back canes with an
outside diameter greater than 1-inch or less than 3/4-inch. Otherwise, injury
or damage may occur.
The mounting position of the Invacare Matrx Mini is directly related to the
chair's stability. When the Invacare Matrx Mini is added to a TILT and/or
RECLINING chair, it may cause a decrease in the chair's stability. It may be
necessary to reposition the FRONT CASTERS, REAR WHEELS, BACK ANGLE,
TILT-IN-SPACE, RECLINE POSITION and/or SEAT DEPTH before use. Use
extreme caution when using a new seating position.
When a Matrx Mini is added to a TILT and/or RECLINING chair, a RIGIDIZER
BAR or CROSSBAR must be present to stabilize the back canes.
Ensure the Invacare Matrx Mini is properly secured to the wheelchair before
using. Otherwise injury or damage may occur.

WARNING!

Skin condition should be checked very frequently after the installation of any
new seating system.
Your therapist and physician should be consulted if you have any questions
regarding individual limitations and needs.
Working with your therapist, physician, and equipment supplier is the best way
to assure that a seating choice matches your individual needs.
As the needs of the individual become more complex, the seating evaluation
becomes more important.

3

1.0  General Warnings

2.0 Hardware Kit Contents

2  -  Mini Mounting Plates
2 -  Cane Clamp Ass’y
2 -  Cane Inserts 

7/8” (22

mm

)

2 -  Cane Inserts

3/4” (19

mm

)

4 -  Depth/Recline Adjustment Screws
2 -  Cane Clamp Screws
2  -  Cane Clamp Nut Plates
4  -  Long Mounting Pins 

(optional)

3.0  Tools Required

Wrench (22

mm

) (provided)

Hex Key Tool (4mm/5mm) (provided)

Utility Knife/Scissors
Tape Measure/Ruler

4

Mini Mounting

Plate

Cane

Clamp

Screw

Cane Clamp

Ass’y

Cane Inserts

Depth/ Recline

Adjustment

Screws

If any of the above hardware is missing or 
misplaced, please contact your local
Invacare/Motion Concepts Representative
to obtain the necessary replacements
parts, or you may contact our Customer
Service Dept. directly for assistance.

Canada:   905-695-0134

USA: 716-447-005

P L E A S E   N O T E

!

3/4”

(19

mm

)

7/8”

(22

mm

)

Cane Clamp 

Nut Plate

(Right Assembly Shown)

Содержание Invacare Matrx Mini back

Страница 1: ...wn good judgement and common sense as well as that of your provider caregiver and or health professional The following symbols are used throughout this manual to identify warnings cautions and importa...

Страница 2: ...wn good judgement and common sense as well as that of your provider caregiver and or health professional The following symbols are used throughout this manual to identify warnings cautions and importa...

Страница 3: ...ILT IN SPACE RECLINE POSITION and or SEAT DEPTH before use Use extreme caution when using a new seating position When a Matrx Mini is added to a TILT and or RECLINING chair a RIGIDIZER BAR or CROSSBAR...

Страница 4: ...ILT IN SPACE RECLINE POSITION and or SEAT DEPTH before use Use extreme caution when using a new seating position When a Matrx Mini is added to a TILT and or RECLINING chair a RIGIDIZER BAR or CROSSBAR...

Страница 5: ...igned to provide 1 5 38mm of fore and aft adjustment relative to the cane clamp To reconfigure a mounting plate cane clamp to the forwardmost orientation detach the Mounting Plate from the Cane Clamp...

Страница 6: ...igned to provide 1 5 38mm of fore and aft adjustment relative to the cane clamp To reconfigure a mounting plate cane clamp to the forwardmost orientation detach the Mounting Plate from the Cane Clamp...

Страница 7: ...e mounting plates see Figure 6 Slide the lower mounting pins into the hooked slots at the bottom of each mounting plate 1 With the lower pins in place lock snap the upper mounting pins into the latch...

Страница 8: ...e mounting plates see Figure 6 Slide the lower mounting pins into the hooked slots at the bottom of each mounting plate 1 With the lower pins in place lock snap the upper mounting pins into the latch...

Страница 9: ...move the backrest from the wheelchair and use the wrench provided to loosen each flange nut If necessary replace the standard mounting pins with long mounting pins iii Adjust the mounting pin depth cl...

Страница 10: ...move the backrest from the wheelchair and use the wrench provided to loosen each flange nut If necessary replace the standard mounting pins with long mounting pins iii Adjust the mounting pin depth cl...

Страница 11: ...cally on the left right mounting plates The vertical lines on the mounting plates are designed as a point of reference to assist with symmetrical mounting see image below The back position can be angl...

Страница 12: ...cally on the left right mounting plates The vertical lines on the mounting plates are designed as a point of reference to assist with symmetrical mounting see image below The back position can be angl...

Страница 13: ...f problems are discovered Corrective measures can be perfomred at or arranged through your equipment supplier 14 8 0 One Hand Cord Release Optional 8 1 Installation Instructions 1 Thread the Nylon Cor...

Страница 14: ...f problems are discovered Corrective measures can be perfomred at or arranged through your equipment supplier 14 8 0 One Hand Cord Release Optional 8 1 Installation Instructions 1 Thread the Nylon Cor...

Страница 15: ...d as needed to meet the needs of the end user 15 WARRANTY Every Invacare Matrx Mini back is carefully inspected and tested to provide optimum performance Each back is guaranteed to be free from defect...

Страница 16: ...d as needed to meet the needs of the end user 15 WARRANTY Every Invacare Matrx Mini back is carefully inspected and tested to provide optimum performance Each back is guaranteed to be free from defect...

Отзывы: