6
For technical assistance call 866-357-8832
MA50777-MNL_revP1
Section B: Adjustment Instructions
!
DANGER:
This controller must be adjusted to ANSI/BHMA A156.10 and
A156.19 standards by a qualified person. Unsafe operation
may result if standards are not met.
!
DANGER:
Never attempt uses which are not covered in this manual.
Serious injury or death may result.
15.
Allow the door to close by removing the activation signal or set the jamb/function
switch to “Auto”.
16.
Reset the controller by momentarily disconnecting power and then restoring power.
17.
Activate the system and the door will go through one sizing cycle. The door can be
activated by momentarily jumpering the activation terminals 16 and 17 (see
“
Wiring
Diagram
”
). Or, the door can also be activated by pushing the door slightly open.
18.
Always wait 5 seconds before reactivating after a sizing cycle.
19.
Using the thumb-turn potentiometers, adjust the door operation. See the attached
“Potentiometer Adjustments”
table in the
“Controller Settings & Adjustments”
section for details. Doors should be adjusted to ANSI/BHMA A156.10 and A156.19
standards and any other applicable standards.
!
DANGER:
This controller must be adjusted to ANSI/BHMA A156.10 and
A156.19 standards by a qualified person.
!
DANGER:
Complete a walk through test. Refer to the latest version of
ANSI/BHMA A156.10 and A156.19 for proper door setup.
Ensure the door is setup to meet all applicable national &
local standards.
20.
Complete a Walk-Through-Test.
Ensure compliance with ANSI/BHMA A156.10 &
A156.19 all applicable national and local standards.
21.
Replace header cover/dress plates.