MA50777-MNL_revP1
7.
Connect the motor harness to the controller’s M1 connector. If using two operators,
connect the slave unit using the slave “extension” harness to the M2 connector.
8.
Select appropriate program for the application. See the attached
“Program Selector”
table in the
“Controller Settings & Adjustments”
section for details.
Operation
Program
Low Energy
0 thru 5
0
1
2 3
4
6
5
A
9
8
7
F
E
D C B
High Energy
A thru D
!
WARNING:
Controller may already be set to High Energy if requested at
time of order, or if the cover seal is broken.
Internal jumper J2 must be in the correct position to permit High Energy programs.
All
units are shipped as Low Energy unless specifically requested to be High
Energy.
See the attached section
“
Controller Settings & Adjustments
”
for details.
!
DANGER:
When using High Energy programs, appropriate safety
equipment must be in place. See ANSI/BHMA A156.10 and
A156.19 standards.
9.
Select DIP switches. See the attached
“DIP Switch Settings”
table in
“Controller
Settings & Adjustments”
section for details.
on
off
1 2 3 4
DIP Switches
Available
Option “ON”
DIP
Switch
Low Energy
Low Energy
/ Low Force
High Energy
Power Boost
1 & 2
Yes
No
Yes
Electric Lock & Delay
3
Yes
Yes
Yes
Push & Go
4
Yes
Yes
No
Safety Stop
(normally Safety Slow)
4
No
No
Yes
!
DANGER:
Doors should be set up according to ANSI/BHMA A156.10 and
A156.19 standards and any other applicable standards.