Moving the microscope 
 

  If possible, avoid moving the stereomicroscope.  

  Carry the stereomicroscope in both hands. One hand should hold the stereomicroscope column (21), and 

the other should support it under the base (13).  

  Maintain the stereomicroscope in a vertical position.

 

 

Repair 

 
If the stereomicroscope needs repairing, or revision by authorised personnel, we would recommend that it be 
stored in its polystyrene box and returned to the distributor. Attach a note with a description of the problem, 
or details of the required revision.  
 

 

Warrantee 
 

All  MOTIC  microscopes  are  warranted  against  any  manufacturing  defect  for  a  5  year  period.  Damage 
occurring  by  any  unauthorised  repair  work,  or  occurring  through  misuse  or  modification  of  the  microscope 
will not be included under the conditions of the warrantee. Bulbs and fuses are not under warrantee.  
 
The  warrantee  service  is  provided  by  MOTIC,  or  its  authorised  distributors.  Defective  products  will  be 
repaired free of charge when returned to MOTIC, or one of its distributors. Transport costs will be covered by 
the purchaser. 
 
 

OWING TO POSSIBLE MODIFICATIONS AND IMPROVEMENTS IN THEIR MANUFACTURE, CHANGES 
MAY OCCUR TO STEREOMICROSCOPES WITHOUT PRIOR NOTICE.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

-12-

 

Содержание SMZ Series

Страница 1: ...Instruction Manual SMZ Series Copyright 02 02 Motic Microscopes European Division...

Страница 2: ...Eyepiece 14 Head 18 Focus knob 20 Support collar screw 22 Incident illumination switch I 23 Transmitted illumination switch T 24 Light intensity control 2 Diopter adjuster 3 Eyepiece tubes 5 Head hold...

Страница 3: ...ents of the stereomicroscope have been carefully packed to make sure they reach you in perfect condition We recommend that you do not discard any packing containers in case you need to return the micr...

Страница 4: ...ent objects or for dissection For best contrast choose the side of the stage to use Warning Transmitted illumination can ONLY be used with the frosted glass stage THE HEAT GENERATED BY THE TRANSMITTED...

Страница 5: ...ntre of the stage 11 3 Turn focussing knobs 18 to mid focus range 4 The head holder 17 is mounted on a column 21 on which it can be moved up or down depending on the size of the object to be focussed...

Страница 6: ...xtended position the image is transmitted to the vertical port but the image cannot be seen by the right eyepiece A To adapt a photographic camera an adapter tube is needed This tube includes 2X lense...

Страница 7: ...hat the CS mount is responsible Place or remove it according to the procedure to obtain parfocality Maintenance WARNING FOR YOUR OWN SAFETY SWITCH OFF AND DISCONNECT THE MICROSCOPE FROM ANY ELECTRICAL...

Страница 8: ...ination bulb a Unscrew the illuminator protector tube 7 turning it anti clockwise and removing the tube from that of the lenses b With a cloth carefully pull out the bulb to disconnect it from the soc...

Страница 9: ...ly as possible without the head sliding down with its own weight The tension adjustment collar for focussing Fig 1 is situated between the focussing knob 18 and the head holder 17 a Loosen the screw l...

Страница 10: ...use cover badly closed Bad connection with power source Insert bulb correctly Replace bulb Close correctly Have repaired by a qualified specialised technician Fuse blown quickly Wrong fuse Replace wit...

Страница 11: ...ils of the required revision Warrantee All MOTIC microscopes are warranted against any manufacturing defect for a 5 year period Damage occurring by any unauthorised repair work or occurring through mi...

Отзывы: