Mostec M2118 Скачать руководство пользователя страница 8

 

M2118

 

Operating Manual

 

 

V1.06 © 17.10.2011 MOSTEC  AG, CH-4410 Liestal 

8

 

K. User menu 
 

Menu access: 

 

press the button (

ENT

) for 4 seconds. 

Navigation within the menu: 

buttons (

+

) and (

-

Select a menu item: 

 

button (

ENT

) (= ENTER) 

Leave a menu item: 

 

button (

ESC

) (= ESCAPE) 

Change a value: 

 

buttons (

+

) and (

-

 

(

ENT

)  

 

â 

 

à

SP_1

 

(

ENT

)

à

  

 

(

+

)/(

-

Adjust setpoint 1 

 

 

ß

(

ESC

)/(

ENT

 

1.053 

 

 

         

**          *

 

 

 

â

 (

+

) / 

á

 (

-

 

à

HSt1 

(

ENT

)

à

 

 

(

+

)/(

-

Adjust hysteresis 1 

 

 

ß

(

ESC

)/(

ENT

 

0.007 

 

â

 (

+

) / 

á

 (

-

 

à

LED1 

(

ENT

)

à

 

 

(

+

)/(

-

LED 1 function normal/inverse 

 

 

ß

(

ESC

)/(

ENT

 

NOR / INR 

 

â

 (

+

) / 

á

 (

-

 

à

REL1 

(

ENT

)

à

 

 

(

+

)/(

-

Relay 1 function normal/inverse 

 

 

ß

(

ESC

)/(

ENT

 

NOR / INR 

 

â

 (

+

) / 

á

 (

-

 

à

SP_2

 

(

ENT

)

à

  

 

(

+

)/(

-

Adjust setpoint 2 

 

 

ß

(

ESC

)/(

ENT

 

1.053 

 

â

 (

+

) / 

á

 (

-

 

à

HSt2 

(

ENT

)

à

 

 

(

+

)/(

-

Adjust hysteresis 2 

 

 

ß

(

ESC

)/(

ENT

 

0.007 

 

â

 (

+

) / 

á

 (

-

 

à

LED2 

(

ENT

)

à

 

 

(

+

)/(

-

LED 1 function normal/inverse 

 

 

ß

(

ESC

)/(

ENT

 

NOR / INR 

 

â

 (

+

) / 

á

 (

-

 

à

REL2 

(

ENT

)

à

 

 

(

+

)/(

-

Relay 1 function normal/inverse 

 

 

ß

(

ESC

)/(

ENT

 

NOR / INR 

 

â

 (

+

) / 

á

 (

-

 

à

Code

 

(

ENT

)

à

  

 

(

+

)/(

-

Change menu access code 

 

 

ß

(

ESC

)/(

ENT

 

0036 

 

â

 (

+

) / 

á

 (

-

 

à

d_2

o

 

(

ENT

)

à

  

 

(

+

)/(

-

Fine-adjust display min. value 

 

 

ß

(

ESC

)/(

ENT

 

0000 

 

â

 (

+

) / 

á

 (

-

 

à

d_GA

 

(

ENT

)

à

  

 

(

+

)/(

-

Fine-adjust display max. value 

 

 

ß

(

ESC

)/(

ENT

 

0000 

 

â

 (

+

) / 

á

 (

-

 

à

i _2

o

 

(

ENT

)

à

  

 

(

+

)/(

-

Fine-adjust current output min. value  

 

ß

(

ESC

)/(

ENT

 

 

0000 

 

â

 (

+

) / 

á

 (

-

 

à

I _GA

 

(

ENT

)

à

  

 

(

+

)/(

-

Fine-adjust current output max. value  

 

ß

(

ESC

)/(

ENT

 

 

0000 

 

â

 (

+

) / 

á

 (

-

 

à

tARe

 

(

ENT

)

à

  

 

(

+

)/(

-

Adjust tare 

 

 

ß

(

ESC

)/(

ENT

 

on / off 

 

 

 

**   

Leave the menu without saving the value 

*    

Leave the menu and save the value

 

 

Содержание M2118

Страница 1: ...erating Manual Alarm Unit Type M2118 Mostec AG Mess und Regeltechnik Lausenerstrasse 13a CH 4410 Liestal Switzerland Tel 41 61 921 40 90 Fax 41 61 921 40 83 Internet www mostec ch E Mail info mostec c...

Страница 2: ...ption The alarm unit M2118 is used to check or control any type of signal current or voltage signal It converts the input signal to an internal standard signal of for example 0 to 100 0 In this range...

Страница 3: ...activating the access code menu values can be observed but no longer modified To modify setpoints and other parameters the access code has to be set to the value 0000 If the code has a value differen...

Страница 4: ...setpoint 8 Change to menu rEL_1 for limit contact 1 or rEL_2 for limit contact 2 by the button or then press ENTER 9 Change relay operating mode by the button or then press ENTER nor Relay ON when inp...

Страница 5: ...e actual measuring value 3 Adjusting a tare value with the menu 1 Press and hold the button ENTER and ESC for 4 seconds The display shows SP_1 indicating the user menu 2 Move to menu item TARE To move...

Страница 6: ...able with adapter to the computer and the display see I page 6 1 start Mpro 2 Choose M2118 in menu Instrument A 3 Choose Adjust for fine adjusting the Gain or Zero B I General references for using the...

Страница 7: ...max 25mA Display Accuracy 23 C ambient temperature z Range adjustment by computer programmable see manual Zero Gain adjustment by computer programmable see manual Alarm contacts t Hysteresis by comput...

Страница 8: ...ay 1 function normal inverse ESC ENT NOR INR SP_2 ENT Adjust setpoint 2 ESC ENT 1 053 HSt2 ENT Adjust hysteresis 2 ESC ENT 0 007 LED2 ENT LED 1 function normal inverse ESC ENT NOR INR REL2 ENT Relay 1...

Отзывы: