Operation
50
NOTES:
1)
R
flashing is generally a user addressable fault / error
2)
R
charging status LED ON with heartbeat blink OFF
every 5 secs is a critical fault that generally requires service.
See,
"Solid Charging Status LED with Self-test (R-Y-G) SOC
Faults",
in Section 5.1.
4.4.3 State-of-Charge LEDs
Battery SOC LED Indications are shown in Table 4-5 below:
Condition
Indication
Absorption
G
flash - every sec
Float
G
flash - every 2 secs
Equalize
G
flash - 2 / sec
SOC > 13.5V
G
solid
13.5V > SOC > 13.0V
G / Y
solid
13.0V > SOC > 12.5V
Y
solid
SOC < 12.5V
Y / R
solid
Low voltage disconnect warning
R
flash - every sec
Low voltage disconnect
R
solid
Table 4.5. Battery SOC LED Indications
4.5 Push-Button Use in Non-Metered Version
The version of the ProStar MPPT without meter display fea-
tures a push-button that operates as follows depending on
the DIP Switch 1 setting:
Normal Mode (DIP 1 OFF)
• One quick press and release will clear any faults or
reminders that are present
• Press and hold for 5 seconds to initiate an Equalization
(EQ), if unit is set to manual EQ.