29
+UNREG
GND/
PGND
VCC
+
UNREG
: Outgoing unregulated 36 V, after interlock relay. Measure between Test
Point +UNREG and Test Point GND/PGND using a voltmeter.
- Voltage should be within 36 V ± 10 %.
- If the machine is interlocked (i.e. the top cover is open), voltage will be 0 V.
VCC
: Stabilised and rectified 5 V made from incoming 10 V AC from transformer.
- Measure between Test Point VCC and Test Point GND/PGND using a voltmeter.
GND / PGND
: Ground /Power Ground is the minus when measuring either unregu-
lated 36 V (+UNREG) or 5 V (VCC).