Manual Part No: 931545-02 MV1 Gas Solid Top Range
- 25 –
Manual Rev No: 1
Service and Maintenance (cont.)
3)
Removal of Oven Burner or Burner Injector.
Remove the shelves and drip tray from inside the oven. This exposes the burner and its supply
tube.
The oven burner injector can be removed for cleaning, etc., without disturbing the burner.
Disconnect the burner supply tube at the union on the injector elbow (immediately before the
burner).
Remove the thermocouple from the burner by unscrewing the M8 nut and easing the
thermocouple tip from the basket (taking note of its position).
Remove the ignition electrode by pulling off the electrode lead, and unscrewing the single screw
securing the electrode to the burner bracket.
The injector elbow can now be unscrewed from the burner thus exposing the injector.
To clean the injector, brush off with a stiff bristle brush any dirt, blow through the orifice to
remove any blockage or restriction -
DO NOT POKE WIRE THROUGH THE INJECTOR ORIFICE
.
To remove the burner: -
Proceed as described above for removing the injector.
Remove the screws at each side of the burner holding the brackets to the oven base.
The burner, complete with its fixing brackets, can be lifted out.
4)
To Remove or clean a Hotplate Injector.
Remove the control knobs and control panel, which is secured by two fixing screws.
Remove the solid top sections, together with the gas tap cover plate (secured by four screws).
Remove the supply pipe to the injector elbow by unscrewing the union-coupling nut.
Unscrew the injector elbow from the burner, thus exposing the injector.
To clean the injector, brush off with a stiff bristle brush any dirt, blow through the orifice to
remove any blockage or restriction –
DO NOT POKE WIRE THROUGH THE INJECTOR ORIFICE
.
5)
To Remove a Hotplate Thermocouple.
Remove the control knobs and control panel, which is secured by two fixing screws.
Remove the solid top sections, together with the gas tap cover plate (secured by four screws).
Undo the fixing nut nearest the thermocouple tip (noting its position relative to the burner).
Unscrew the thermocouple from the Gas Tap/FFD and withdraw the thermocouple.
Replace by reversing the above procedure.
When re-fitting the thermocouple, ensure that the sensing tip is positioned correctly with the tip
inside the flame pattern.
Tighten the connection to the thermostat finger tight and then add a further ¼ turn using a
spanner,
DO NOT OVER-TIGHTEN
– this can break the seal and continuity