background image

 

 9

TRUNKGUARD™ 

Series Fieldbus Device Couplers

(Zone 1 Locations)

TG300

Maintenance

The TG300 series contain no user serviceable parts. 
Non-functioning units should be returned to Moore 
Industries for replacement or repair.

WARNING:

 

Substitution of components may impair 

the device coupler, wiring and field device 

suitability for hazardous area applications.

Note:

 

When returning non-functioning units only 

the DIN-Rail mounted electronics should be 

returned.  It is normally prudent to retain the 

enclosure, glands, and connectors with their 

terminals attached when a device coupler is 

changed out in the field.

TG300 enclosures have weatherproof seals on 
enclosure lids and on cable glands; these should be 
periodically inspected to verify correct operation. Any 
significant water entry should be investigated and 
corrected in order to prevent malfunction.

In high humidity environments, it may be appropriate 
to have enclosure breathers fitted so that internal 
condensation does not lead to equipment malfunction.

Customer Support

If service assistance is ever required for an instrument 
in your application, refer to the back cover of this 
manual for the telephone numbers to MooreHawke 
Customer Service Department. 
 
If possible, make a note of the model number of the 
unit before calling.  For fastest assistance, have the 
following available: serial number, job number or 
purchase order number.

Operation

Each spur has three LEDs indicating the following 
states: 

Normal, Fault 

and 

De-Energized

.

During normal operation, the GREEN LEDs should be 
ON for all spur connections. 

If any RED LED(s) are ON, the affected spur(s) have 
fault(s) in external wiring or field device(s).  Please 
refer to the 

Testing and Troubleshooting

 section..

Use the DISCONN Key to de-energize that spur, 
remove the wiring and then re-energize it by removing 
the DISCONN Key.  This spur now has no device 
connected, and the GREEN LED should turn ON with 
the RED LED turning OFF.  Use this to confirm a fault 
in the spur wiring or field device. 

Segment termination is automatically provided by 
the last TG300 unit connected in the segment, and 
operation is indicated by a YELLOW LED labeled 

Active Auto Terminator*.

*Auto-terminator function not applicable with -MT option.

Содержание Hawke TRUNKGUARD Series

Страница 1: ...TG300 TG300 May 2016 920091D TRUNKGUARD Series Fieldbus Device Couplers Zone 1 Locations TRUNKGUARD Series Fieldbus Device Couplers Zone 1 Locations...

Страница 2: ...oupler Enclosures 3 Specifications 4 Dimensions 4 Installation 6 Wiring Connections 6 Device Coupler Hook Up 6 DISCONN Key 7 Recommended Ground Wiring Practices 7 CE Conformity 8 Testing and Troublesh...

Страница 3: ...you see a Note Caution or WARNING pay particular attention WARNING Hazardous procedure or condition that could injure the operator Caution Hazardous procedure or condition that could damage or destro...

Страница 4: ...Internal Automatic Segment Termination is standard For manual Communications Performance termination specify the MT option with the MooreHawke model number e g TG308 DIN MT Also separately specify a T...

Страница 5: ...Enclosure Installation Dimensions 8 Spur Model 4 Spur Model OUT IN 1 2 3 4 250mm 9 85 in 200mm 7 87 in 120mm 4 72 in 255mm 10 04 in 235mm 9 25 in OUT IN 1 2 3 4 5 6 7 8 255mm 10 04 in 235mm 9 25 in 25...

Страница 6: ...e of installation Cables should be brought to the device coupler in such a way as to prevent external water from running into the cable entry position For cables coming vertically down to a device cou...

Страница 7: ...ded to an external earth stud DISCONN Key The DISCONN Key contains the magnet used to operate the magnetic interlock which permits individual fieldbus devices to be de energized and worked on without...

Страница 8: ...a core to shield fault on that spur cable Locate and repair any spur fault before reconnecting that spur All LEDs are OFF Any red LED is ON Table 1 LED Indications Testing and Troubleshooting Testing...

Страница 9: ...Customer Support If service assistance is ever required for an instrument in your application refer to the back cover of this manual for the telephone numbers to MooreHawke Customer Service Department...

Страница 10: ......

Страница 11: ...IES FOR BREACH OF ANY WARRANTY CONCERNING THE GOODS OR SERVICES SHALL BE FOR THE COMPANY AT ITS OPTION TO REPAIR OR REPLACE THE GOODS OR SERVICES OR REFUND THE PURCHASE PRICE THE COMPANY SHALL IN NO E...

Отзывы: