4.4.5 Fieldbus address menu (Fb)
The functions available under this menu item depend on the device expansion option.
For detailed information refer to the relevant specification.
Menu level Param-
eter
Value
range
Meaning
Explanation
1
2
Fb
Ad
-
00..xx
or
- -
Fieldbus address
Setting of fieldbus address (only when
fieldbus option used), otherwise display
"- -"
(The maximum programmable value
depends on the option)
Po
-
0..3
or
- -
Transmit power
Setting of fibre-optic power output
(only with SERCOS II option), otherwise
display "- -"
Table 4.10 Fieldbus address menu
Example configuration of fieldbus address
In this example the fieldbus address is changed from 1 to 23.
NOTE:
Changes on the fieldbus address menu are only saved when the
control electronics are subsequently restarted.
Tx
Tx
T2
T2
T1 T2
T1 T2
T1 T2
>5 s
>5 s
<5 s
<5 s
T1 T2
T1 T2
T1 T2
T1
T2
T1
Back
Back
Press button
T
x
(X= 1,2) repeatedly
until desired menu
appears on display
Back
Apply
Value NOT
saved
Value
saved
Press button
T
x
(X= 1,2) once
Press any button
Press buttons T1
and T2 simultaneously
Fig. 4.3 Example configuration of fieldbus address