MSD Single-Axis System Operation Manual AC-AC Servo Drive
ID no.: CA65642-001 06/2018
moog
77
A.2.6
G395-250 to G395-450, liquid cooling
Designation
Technical data
G395-250
G395-325
G395-450
Output, motor side
1)
Voltage
3)
3-phase U
Mains
Rated current, effective (l
N
)
250 A
325 A
450 A
Peak current
See A.1.6
Rotating field frequency
0 ... 400 Hz
Switching frequency of the power stage
2, 4 kHz (8, 12, 16)
2)
Input, mains side
Mains voltage
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
Device connected load (with mains choke)
173 kVA
225 kVA
310 kVA
Current
1)
(with mains choke)
250 A
325 A
450 A
Asymmetry of mains voltage
±3 % maximum
Frequency
50/60 Hz ±10 %
Power dissipation at I
N
1)
3960 W
4800 W
6750 W
DC link
Capacitance
3600 µF
5400 µF
7200 µF
Brake chopper switch-on threshold
820 V DC
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 4 kHz
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.14 Technical data G395-250 to G395-450 liquid cooling
Designation
Technical data
G395-250
G395-325
G395-450
Minimum ohmic resistance of an externally installed
braking resistor
3.2 Ω
3)
2.5 Ω
3)
1.7 Ω
3)
Brake chopper peak power
with external braking resistor
210 kW
269 kW
395 kW
Option: internal braking resistor
3.3 Ω
2.4 Ω
Brake chopper continuous power
with internal braking resistor
5000 W
6800 W
Brake chopper peak power
with internal braking resistor
204 kW
280 kW
Chiller data
Coolant pressure
(rated value / maximum value)
1 / 2 bar
Coolant flow rate
4)
(rated value / maximum value)
11 / 13 l per min
Feed coolant temperature
The coolant temperature can be b5 °C (+41 °F) and
+40 °C (+104 °F). However, the coolant temperature should
not be more than 10 °K below the ambient temperature to
prevent condensation on the heat sink.
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 4 kHz
2)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
3)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
4)
Cooling performance adequate also with optional internal braking resistor
Table A.14 Technical data G395-250 to G395-450 liquid cooling
Содержание G305-170
Страница 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Страница 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 60: ...60 Diagnostics MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...