background image

Page 2/3

Mounting and Installation Notes

 

D765/9

 

(B97072-765-001; Version

 

H

)

3 Installation

Compare model number and type with that specified on hy-

draulic schematic. The valve can be mounted in any position,

fixed or movable. 

Mounting surface:

 Check for flatness

(< 0.01 mm (0.00004 in) over 100 mm (3.94 in)) and finish

(R

a

< 0.8 µm). Care must be taken to ensure that contamina-

tion does not enter the hydraulic system, all work areas must

be clean of surface or air-borne contamination.

Mounting:

 Socket head screws (grade 10.9) according to

EN ISO 4762, torque diagonally alternating.

4 Pilot Mode and Maximum Pressures

Pilot mode:

 Pay attention to the hydraulic connection scheme

and to the mounting pattern of the hydraulic manifold. Pay at-

tention to the hydraulic schematic on the valve nameplate and

to the type designation defining the pilot mode. 

Maximum pilot and operating pressure (p

X

, p

P

):

 See name-

plate.

5 Electrical Connection

Electrical safety: 

The protective conductor connection is con-

nected to the electronics housing or valve body. The insulation

materials employed are designed for use in the safety extra-

low voltage range. 

To comply with safety regulations requires isolation from the

mains according to EN 61558-1 and EN 61558-2-6 and limiting

all voltages according to EN 60204-1. We recommend using

SELV/PELV power supplies.

Rated signal:

 See nameplate.

External fuse per valve:

 0.5 A medium time lag

Valve phasing:

 A positive signal (D–E) causes valve opening

P

B.

Connector wiring:

 See wiring schematic in the catalog or the

installation drawing.

Connection:

 

Before  applying  electric  signals  the  pilot 

stage  has  to  be  pressurized.

Signal lines shielded, shielding connected at

 

both ends and 

additionally  connected  to  reference  potential

 

(0

 

V)  at  the 

control  side  (to  improve  EMC).  Connect  the  protective 

conductor. 

Observe  technical  notes  TN353  Protective 

Grounding  and  Electrical  Shielding,  TN426  Wiring  Instructions 

and TN494 Maximum Permissible Length of Electric Cables.

 

6

 

Hydraulic System Start Up

Pay attention to the pressure setting, the venting instructions

 

and the alarm messages!

7

 

Null Adjustment 

Remove the locking screw with sealing ring from the motor cap

 

to  access  the  null adjustment potentiometer.  Turning the po-

tentiometer shaft results in a spool position change. Turning

 

clockwise  will  increase  valve  opening  P

B(C2).  The  output

 

signal for actual spool position will also change. After adjust-

ment refit the sealing ring and the locking screw.

8

 

Maintenance

Except for a regular visual inspection for exterior leakage and

 

filter change, no maintenance work on the valves is required.

 

Changing the filter: 

The installed filter protects internal ori-

fices and nozzles against coarse particle contamination. The

 

valve response time will increase as contamination increases.

 

The filters located below the filter cover at the side may be re-

placed by the customer.

• Remove hexagon socket screws (5) with a wrench and

remove the filter cover (4). Remove the filter disk (2),

which is now accessible, with tweezers or a fine screw-

driver.

Fig.: Principles of construction

• Check O-rings (1) and (3) and replace if necessary.
• Install new filter disk. To do this, first insert the O-Ring

(1), then the filter disk (2) so that the side of the filter disk

with the indentation faces the outside. Insert O-ring (3) in

the filter cover (4) with some clean grease and mount.

NOTICE

Damage due to dirt, moisture and ozone/UV effects

• Storage outside or under the wrong climatic conditions can

cause corrosion and other damage to the valve. Conden-

sation due to temperature fluctuations can result in elec-

tronic malfunctions.

In the case of intermediate storage, observe the follow-

ing storage conditions:

• Recommended ambient temperature: +15 to +25 °C

(+60 to +78 °F), permissible temperature: –40 to

+80 °C (–40 to +176 °F), temperature  fluctuation:

< 10 °C  (18 °F)

• Relative humidity: < 65 % not condensing
• Ensure there are minimal vibration and shock where

valves are stored

Following transport or storage, wait until the valves have

reached ambient temperature before starting up.

• Dirt and moisture can enter the valve through openings

and cause damage. Seals can be damaged due to the

effects of ozone and UV.

During storage and transport, seal connectors with dust

protection caps and install the shipping plate on the

mounting surface.

Remove dust protection caps and shipping plate only

shortly before mounting the valves and keep packaging

materials for future storage and transport.

Seal with protection caps any valve connectors that are

not used in operation (without mating connector).

Series

Socket head screw

Pcs.

Torque [Nm] 

(lbf in)

D765

M8 x 45

4

18

D769

M8 x 45

4

18

NOTICE

Changing the filter

Cleaning serves no purpose.

NOTICE

Fluid flow through the filter disk (2) is from inside to outside

leaving particles behind the filter disk (2) and cannot be seen

from the outside after removing the filter cover (4).

NOTICE

Before beginning work, clean the outside of the valve

around the filter cover!

4

5

3

2

1

©

199

9, 20

03,

 20

08,

 2

009,

 2010

 Moo

g

G

m

bH,

 

Hann

s-

Klemm-S

tr

.

28,

7103

4

B

öblin

gen,

GERMA

N

Y

, www.moo

g.

co

m

/in

dustr

ial

A

ll rig

hts reserved

. Sub

ject t

o c

hange

s.

Содержание D765/9 Series

Страница 1: ...hme Hinweise Baureihen D765 9 Servoventile Manuel de l utilisateur Instructions de mise en service S ries D765 9 Servovalves Manuale dell utilizzatore Istruzioni di montaggio ed installazione Serie D7...

Страница 2: ...hine depres surize all hydraulic lines and accumulators When mounting the valves observe the specifica tion of the installation screws and the mounting pattern and ensure the presence elasticity integ...

Страница 3: ...king screw 8 Maintenance Except for a regular visual inspection for exterior leakage and filter change no maintenance work on the valves is required Changing the filter The installed filter protects i...

Страница 4: ...t is not damaged during transportation or stor age Inspection Following a period of storage or no operation for more than 5 years we recommend that the valve is inspected by an authorized service cent...

Страница 5: ...stritt am Ventil Schwitzen WARNUNG Falsche Handhabung Falsche Handhabung von Ventil Werkzeug oder Zu beh r kann Todesf lle schwerste K rperverletzung und erheblichen Sachschaden verursachen Arbeiten m...

Страница 6: ...n Betrieb setzen Druckwerteinstellung Entl ftungsvorschrift und St rmeldun gen beachten 7 Nulleinstellung Nach Entfernen der Verschlussschraube samt Dichtring an der Motorkappe wird ein Mehrgang Poten...

Страница 7: ...achten Transport Lagerung Vor dem Transport eines Ventils die Ventilgrundfl che mit einer sauberen Staubschutzplatte oder Klebeband abdichten Die Anbaustecker mit einer Staub schutzkappe abdichten Ven...

Страница 8: ...stallations s assurer que les accumulateurs et conduites soit d pressuris s Lors du montage des commandes suivre les ins tructions concernant les vis et la surface de mon tage et assurer la pr sence l...

Страница 9: ...de la position r elle du tiroir volue alors Apr s l ajustement remettre la bague d tanch it et la vis bouchon 8 Maintenance Le client est autoris remplacer les filtres situ s sur le c t sous le couve...

Страница 10: ...cable de la valve et de l envi ronnement de travail Transport stockage Avant le transport scellez la base de la valve l aide d une plaque de transport propre ou de ruban ad h sif Scellez le connecteur...

Страница 11: ...n guasto del componente AVVERTENZA Scorretta manipolazione Una scorretta manipolazione di valvole utensili o at trezzature pu causare decessi gravissime lesioni corporee e notevoli danni materiale Lav...

Страница 12: ...a idraulico Fare attenzione alla taratura della pressione alle istruzioni di spurgo dell aria ed ai messaggi di allarme 7 Regolazione dello zero Rimuovere la vite di chiusura con la guarnizione dal co...

Страница 13: ...are at tenzione alla pulizia della valvola e dell area circostante Trasporto stoccaggio Prima di effettuare il trasporto sigil lare la base della valvola utilizzando una piastra di trasporto pulita o...

Страница 14: ...dr ulicas y el acumulador hidr ulico est n libre de presi n Durante el montaje de la v lvula se deber n aca tar las especificaciones t cnicas de los tornillos de fijaci n y de la superficie de montaje...

Страница 15: ...ente el valor real de posici n de corredera Despu s de realizar los ajustes volver a colocar la junta de sellado y el tornillo de fijaci n 8 Mantenimiento Salvo un control visual para detectar fugas e...

Страница 16: ...cambiadas por el cliente Al hacerlo es imprescindible que la v lvula y el entorno de mon taje est n limpios Transporte almacenamiento Antes del transporte selle la base de la v lvula con una placa de...

Страница 17: ...3767 info japan moog com Korea 82 31 764 6711 info korea moog com Luxembourg 352 40 46 401 info luxembourg moog com The Netherlands 31 252 462 000 info thenetherlands moog com Norway 47 6494 1948 info...

Отзывы: