background image

- 8 -

Example 2

: Connect the coaxial cable between the

video output connector on the WV-CS404 and the

camera input connector on the WV-CU254.

Note

: For the connections  in the diagram, refer to

the operating instructions for each product.

Example 3

:  Connect the coaxial cable between the

video output connector on the WV-BS204, WV-CS404,

WV-CS604 and the camera input connector on the

WV-CU254.

SPECIFICATIONS

MECHANICAL/ELECTRICAL

Upper Housing -

 .25" high impact, UV-stable white plastic

Housing Bracket -

 14- and 16-gauge steel

Lower Dome -

 7" distortion-free acrylic

Unit Weight -

 Camera  4.4 lbs.; domed housing 6.6 lbs.

Environmental -

 -20

°

 to 120

°

 F

Heater -

 On at 40

°

 F, off at 60

°

 F  (+/-5

°

) 60  vA

Blower -

 Continuous, .11A

Surge Protector :

  

Video clamping -

 Differential mode 27-36V

       common mode 54-72 V

  Power clamping - 240 - 300V

STANDARD CONFIGURATION

Item or Sub-Item

Description

20-DCPOD7

7" CLEAR DOME POD7

21-TOPOD7

HOUSING TOP FOR POD7

30-VL1372

UPPER HOUSING BRACKET, POD-7C

30-VL1379

LANYARD ,7" DOMES

30-VL917

POD-12C 2 1/4" COUPLING

30-VL926

POD12C MOUNTING BRACKET

40-BRPOD7

BRACKET ASSY POD7

30-VL1371

LOWER HOUSING BRACKET, POD-7C

60-WPBNC1

BNC PLUG 75 OHM FOR RG 179

70-WPMX01

WM3701 (4) CIR/PLUG

70-WPMX02

Molex 39-00-0039 FEMALE PIN

71-BLEH24

24VDC Blower .11A

72-HTPOD12

24VAC Heater 50 Watts

76-PODPCB

PC Board Assembly

90-BTRP19

8-32 X 3/8 RD HD PHIL SS

91-NTHH06

8-32 HEX NUT SS

92-WSTH02

#8 EXT TTH STAR L/W STAINLESS

94-FSCT01

CABLE TIE NYLON NAT.

94-FSSR03

HEYCO 1060 SR 2M-1 BLK STRAIN

95-MX2025

MOLEX RECEPTACLE

95-PCST02

TTW FASTEX PCB SUPPORTS

95-PCST03

ITW FASTEX 232-120207-30

40-CAPOD701

COAXIAL CABLE ASSY. FOR POD7

40-CAPOD702

POD-12C CABLE ASSY. B

40-PKPOD7

PACKET ASSY FOR POD7C

70-WPMX10

Molex 39-01-4030

90-BTHH32

1/4-20 X 1/2" HX HD SS MS

90-BTHH39

1/4-20 x 3/8" HX HD SS MS

90-BTSS05

1/4-20 x 1/2" SET SCREW

92-WSFL01

1/4 SAE FLAT WASHER 18-8 SS

92-WSSL01

1/4 SPLIT LOCKWASHER 18-8 SS

94-FSLG01

 HEYCO WIRE HOLDER  #3630 WT

94-FSRT01

RETAINER BLACK NYLON

95-FSSL03

HOOK LOOP CABLE POD12C

95-FSSL04

CABLE FERRULES

95-FSTS03

TOOLHEAD SCREW

96-PSGK04

VL-1433 POD-12C TOP GASKET

96-PSGK05

VL-1014 POD-12C BOTTOM GASKET

Содержание POD7C

Страница 1: ...for Before attempting to connect or operate this product please read these instructions completely Installation Instructions Outdoor Domed Housings POD7C POD7CW Manufactured By ...

Страница 2: ...ically examine the unit and the supporting structure to make sure that the integrity of the installation is intact Failure to comply with the foregoing could result in the unit coming loose from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit PRECAUTIONS ON INSTALLATION Installation should be in accordance with all applicable loca...

Страница 3: ...t 3 White Upper Top 4 Housing Gasket 5 White Upper Top B Bracket Assembly 1 Upper Housing Bracket 2 Lower Housing Bracket 3 24 VDC Blower 4 24 VAC Heater 5 PC Board Assembly C Dome Assembly 1 7 Clear Plastic Dome 2 3 Security Fasteners D Housing Packet 1 Security Tool 2 4 8 x 32 Bolts 3 2 Molex Connector w 6 Pins 4 Instruction Manual 5 1 4 x 20 x 1 2 Bolt 6 1 4 Flat Washer 7 1 4 Lock Washer 8 Plas...

Страница 4: ... 4 2 1 4 Coupling Mounting Bracket Top Gasket Housing top Upper Housing Bracket Lower Housing Bracket Camera 7 Clear Dome Housing Assembly Bracket Assembly Dome Assembly Or Wall Mount ...

Страница 5: ...t PSRCW 2000 Corner Mount Bracket PCA 2 Pole Mount Bracket PPM 3 5 3 INSTALLATION 3 1 Camera Installations Snap out the area X from the unitized camera for thecablesexiting Alongnoseplierisrecommended Note Round off all sharp edges with file to avoid injury Attach camera mount bracket of unitized camera to dome bracket using the standard screw A Attach the unitized camera to dome bracket first han...

Страница 6: ...5 or 57026 5000 for UL listed style cable UL1007 After clamping the contacts push them into the proper holes in the connector housing until they snap in place 1 1 2 2 3 3 4 4 Approx 0 1 Wire Insert Up Contact Wire Up Contact 6 CAUTIONS Shrinking the cable entry seal is a onetime procedure Do not shrink the cable entry seal until it has been determined that the unit is functioning CONNECT THIS TO A...

Страница 7: ...ure Compressed air cans are available for this use at most photography supply stores If the surface doesn t clean properly with compressed air use a nonabrasive cleaner that is acceptable for use on acrylic Do not use any other type of cleaner This may result in scratches to the dome s surface For service of Panasonic Videolarm equipment contact Panasonic Technical Center 52 West Gude Dr Rockville...

Страница 8: ...RD 7 DOMES 30 VL917 POD 12C 2 1 4 COUPLING 30 VL926 POD12C MOUNTING BRACKET 40 BRPOD7 BRACKET ASSY POD7 30 VL1371 LOWER HOUSING BRACKET POD 7C 60 WPBNC1 BNC PLUG 75 OHM FOR RG 179 70 WPMX01 WM3701 4 CIR PLUG 70 WPMX02 Molex 39 00 0039 FEMALE PIN 71 BLEH24 24VDC Blower 11A 72 HTPOD12 24VAC Heater 50 Watts 76 PODPCB PC Board Assembly 90 BTRP19 8 32 X 3 8 RD HD PHIL SS 91 NTHH06 8 32 HEX NUT SS 92 WS...

Страница 9: ... 9 Rev 3029 0200 114 7 000 2 084 12 861 1 405 9 169 14 169 089 7 000 3 432 Set Screws Slot safety screw located on both sides Gasket Coupling for 1 1 2 standard pipe ...

Отзывы: