Assemble the power cable with the provided
connector (included in housing packet).
Front view of the female connector in housing cable.
Pin 1 is in the lower right hand corner.
Connector A - Camera Power
Connector B - Heater/Blower Power
Connector Information Pin
1
. AC 24 VAC Live
2
. AC 24 VAC Neutral
3
. Not Used
4
. Ground
CAUTION
: For lightning protection of the camera
and heater/blower, the pin 3 of the connector must
be connected to real electrical ground.
HOW TO ASSEMBLE THE CONNECTOR
• Strip back the cable jacket approximately 0.1 inch
(3 mm) and separate the individual conductors.
Prepare the individual conductors for clamping. If
clamping, use Molex brand tool part number 57027-
5000 (for UL-listed-style cable UL1015) or 57026-5000
(for UL-listed-style cable UL1007).
After clamping the contacts, push them into the
proper holes in the connector housing until they snap
in place.
1
1
2
2
3
3 4
4
Approx. 0.1"
Wire
Insert
Up
Contact
Wire
Up
Contact
- 6 -
CAUTIONS
• Shrinking the cable-entry seal is a onetime
procedure. Do not shrink the cable-entry seal until
it has been determined that the unit is functioning.
•
CONNECT THIS TO A 24 VAC CLASS 2 POWER
SUPPLY ONLY.
CAUTION
: TO PREVENT FIRE OR SHOCK HAZARD, THE
UL-LISTED WIRE VW-1, STYLE 1007, SHOULD BE USED
FOR THE CABLE FOR 24 VAC INPUT TERMINALS.
OPERATING DISTANCES
Awg Size
Impedance
Max Distance
Awg #12
1.71 ohm/1000 ft.
440 ft.
Awg #14
2.73 ohm/1000 ft.
270 ft.
Awg #16
4.35 ohm/1000 ft.
170 ft.
Awg #18
6.92 ohm/1000 ft.
100 ft.
3-4 Pendant POD7C- Connections
Attach coupling to 1 1/2 NPT thread pipe. Note: Seal
thread with a bead of silicone sealer to ensure
water-tight fit.
1
2
4
3
1
2
4
3