INSTALLING QUICK RELEASE BRACKETS
AXIS 231D/232D
2685 Mounting Plate:
Attach camera using these (3) holes
1. The AXIS 231D/232D mounts to the 2685 mounting plate
using the (3) locking pins on the base of the pan tilt.
2. Hold pan/tilt with dome facing down, and find “tab” on
the bottom of the unit. Loosen the screw which is to the
right of the tab by approximately 5 turns.
3. Position the locking pins and locking screw over the key
hole slots and twist clockwise. Secure locking screw.
4. The AXIS 231D/232D cameras require ½” of spacing for
optimal position within the housing. Use (4) ½” spacer
provided in the packet.
5. Place (3) 8 x 32 x
s
Phillips head screws on the top
of the spacer as shown above. Be sure to place the
screws so that they line up with the open slots on the
mounting plate.
6. Slide the mounting plate with camera into position on
top of spacers. Secure 3 screws and captive fastener.
½"
Keyhole slot (3)
Loosen screw
Locking screw
Small keyhole
slot
Locking pins