background image

Fig.11

Fig.12

Closed position 
maximun position 
minimum position

Burners

3000W

Semi-rapid

1750 W

Auxiliary

1000W

φ Pans (cm)

20-22

24-26

16-18

10-14

Rapid 

Triple Flame 

3800/3500W

Correct Disposal of This Product:

This marking indicates that this product should not be disposed of together with 

other household waste. To prevent possible harm to the environment or human 

health from uncontrolled waste disposal, recycle it responsibly to promote 

sustainable re-use of material resources. To return your unwanted product, please 

use local return and collect systems or contact the retailer where the product was 

purchased.  They should be able to take the appliance for environmentally-safe 

recycling.

8

INJECTOR REPLACEMENT TABLE

1.

 

18

BURNERS

NORMAL 

PRESSURE

NORMAL 

RATE

INJECTOR 

DIAMETER

NOMINAL HEAT 

INPUT (kW)

DESCRIPTION

GAS

mbar

kW

mm (error ±0.01)

MIN.

1

2

3

RAPID

28-30 

37 20

0.86

0.86

SEMI-RAPID

28-30 

37 20

0.67

0.67

0.97

AUXILIARY

BUTANE

PROPANE

NATURAL

BUTANE

PROPANE

NATURAL

BUTANE

PROPANE

NATURAL

BUTANE

PROPANE

NATURAL

28-30 

37 20

0.49

0.49

0.72

1.2

1.2

0.8

0.8

0.8

0.6

0.6

0.6

3.0

3.0

3.0

1.75

1.75

1

1

1

1.2

1.75

4

2.6

2.6

2.6

3.8/3.5

3.8/3.5

3.8/3.5

1.0

1.0

1.35

TRIPLE

FLAME

28-30 

37 20

5.  USER INSTRUCTIONS

1. To light the hob, push down the appropriate knob and turn anti-clockwise to the large flame symbol 

(Fig.11).

2. Keep the knob depressed until the burner lights.

3. Turn the knob to the required setting.

4. In the event of the burner flames being accidentally extinguished, turn off the burner immediately and 

do not attempt to reignite for at least 1 minute.

NOTE: Matches can be used to light the burners in the event of a power failure.

Keep the control knob pressed in for 15 seconds ensuring the burner stays lit when released.

If the burner fails to stay lit wait for 1 minute before relighting.

SELECT THE RIGHT BURNER

Use an appropriately sized pan with a flat bottom for each burner (see the table below and Fig.12). When 

the contents of the pan start to boil, turn the knob down to reduced rate position. Always put a lid on the 

pan. 

 

NOTE: Please do not use pots or pans that overlap the boundaries of the hob.

Содержание MGB60X

Страница 1: ...G Please read these instructions carefully before attempting to install or use this appliance We recommend that you keep these instructions in a safe place for future reference Installation and Operat...

Страница 2: ...ssured that you are fully protected against the cost of repairs for the first 24 months Please note that any claim must be accompanied by the model reference number serial number and proof of purchase...

Страница 3: ...s kept clean 8 This appliance is designed for domestic cooking only Commercial use will invalidate the warranty 9 Do not cover the hob or place combustible materials on or near the surface even when t...

Страница 4: ...urner 3000W Triple flame gas burner 3800W Triple flame gas burner 3800W Semi rapid gas burner 1750W Semi rapid gas burner 1750W Semi rapid gas burner 1750W Semi rapid gas burner 1750W 3 Auxiliary gas...

Страница 5: ...ection must be carried out by qualified personnel only The safety and automatic adjustment devices of the appliance may only be modified by an authorised service agent The installation of this gas hob...

Страница 6: ...ing appliances in the same room BS5440 Part 2 should be consulted to determine air vent requirements NOTE The use of a gas cooking appliance results in the production of heat and moisture in the room...

Страница 7: ...ing purposes only It must not be used for other purposes for example room heating When fitting a gas hob above a drawer or a standard housing unit suitable precautions must be taken to prevent contact...

Страница 8: ...75CX MGH75BG 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 4 7 GAS CONNECTION QUALIFIED PERSONNEL ONLY The appliance has an G 1 2 threaded pipe connector to connect it to the g...

Страница 9: ...ROPANE NATURAL BUTANE PROPANE NATURAL BUTANE PROPANE NATURAL 28 30 37 20 0 49 0 49 0 72 1 2 1 2 0 8 0 8 0 8 0 6 0 6 0 6 3 0 3 0 3 0 1 75 1 75 1 1 1 1 2 1 75 4 2 6 2 6 2 6 3 8 3 5 3 8 3 5 3 8 3 5 1 0 1...

Страница 10: ...ccording to EN 30 2 1 1998 A1 2003 A2 2005 The semi rapid burner and rapid burner were tested separately the auxiliary burner is not required for test because its nominal heat input is less than 1 16k...

Страница 11: ...nt misuse unauthorised modification or inexpert repair Cost of Call out where a fault cannot be found with the appliance Cost of Call out for work covering routine maintenance such as but not exclusiv...

Страница 12: ...l help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about...

Отзывы: