2. YOUR HOB

Applicable for Gas

3. CLEANING

CAST IRON OR ENAMELLED PARTS

In order to clean the hotplate, burner caps and pan supports on your hob, please use a soft cloth and hot, 

soapy water.

Stubborn stains can be removed with a non-abrasive cleaning agent, so as not to damage the enamel 

surface.

NOTE:  The enamelled pan supports can also be cleaned safely in the dishwasher. 

STAINLESS STEEL

To clean the hotplate surface, clean with a cloth soaked in hot, soapy water and then dry with a soft cloth 

to avoid scratching. 

PLASTIC

To clean the control knobs, wipe clean with a damp, soapy cloth.

GLASS

A non-abrasive cleaner should be used on glass surfaces.

Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. 

Glass can be effectively cleaned by simply using a dilute solution of water and mild detergent and drying 

to a shine with a clean cloth.

4. INSTALLATION INSTRUCTIONS

TECHNICAL INFORMATION

The installation, adjustments, conversions and maintenance listed in this section must be carried out by 

qualified personnel only.

The safety and automatic adjustment devices of the appliance may only be modified by an authorised 

service agent.

The installation of this gas hob must comply with UK standards.

This appliance must be fitted in compliance with the installation rules given above.  Also, particular 

attention must be given to the following requirements for ventilation.

Rapid 

gas 

burner 

Semi-rapid

gas

burner

burner

Auxiliary

gas

Material

Flame

failure

device

Power

Supply

Size

(mm)

Built-in

(mm)

Type

580x500x90

580x500x85

580x510x100

700x510x100

303x520x95

297x515x85

Yes

 1.1W

 1.1W

 1.1W

 1.1W

 1.1W

Triple flame

 gas burner

283x498

283x498

3.0kW

3.0kW

1.75kW

AC 220-

240V 

50Hz

Yes

557x477

557x477

557x477

557x477

557x477

Glass

Glass

Yes

3

.

5kW

1.75kW

1.0kW

Yes

3

.

8kW

1.75kW

1.0kW

/

/

/

/

/

/

/

1.75kW

680x500x90

860x500x90

860x510x100

837x477

837x477

MGB60X

Rated 

Electric

Input

Stainless

steel

Stainless

steel

Yes

 2.0W

3

.

8kW

3.0kW

1.75kW

1.0kW

Yes

 2.0W

3

.

8kW

3.0kW

1.75kW

1.0kW

Stainless

steel
Glass

Glass

Yes

Yes

 2.0W

3

.

8kW

3.0kW

1.75kW

1.0kW

Yes

 2.0W

3

.

8kW

3.0kW

3.0kW

1.75kW

1.75kW

1.0kW

1.0kW

Stainless

steel

Stainless

steel

4

MGH61BG

MGH75CX

MGH30X

MGH30BG

MGH75BG

MGH90CX

MGH90BG

MGH61CX

Содержание MGB60X

Страница 1: ...G Please read these instructions carefully before attempting to install or use this appliance We recommend that you keep these instructions in a safe place for future reference Installation and Operat...

Страница 2: ...ssured that you are fully protected against the cost of repairs for the first 24 months Please note that any claim must be accompanied by the model reference number serial number and proof of purchase...

Страница 3: ...s kept clean 8 This appliance is designed for domestic cooking only Commercial use will invalidate the warranty 9 Do not cover the hob or place combustible materials on or near the surface even when t...

Страница 4: ...urner 3000W Triple flame gas burner 3800W Triple flame gas burner 3800W Semi rapid gas burner 1750W Semi rapid gas burner 1750W Semi rapid gas burner 1750W Semi rapid gas burner 1750W 3 Auxiliary gas...

Страница 5: ...ection must be carried out by qualified personnel only The safety and automatic adjustment devices of the appliance may only be modified by an authorised service agent The installation of this gas hob...

Страница 6: ...ing appliances in the same room BS5440 Part 2 should be consulted to determine air vent requirements NOTE The use of a gas cooking appliance results in the production of heat and moisture in the room...

Страница 7: ...ing purposes only It must not be used for other purposes for example room heating When fitting a gas hob above a drawer or a standard housing unit suitable precautions must be taken to prevent contact...

Страница 8: ...75CX MGH75BG 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 4 7 GAS CONNECTION QUALIFIED PERSONNEL ONLY The appliance has an G 1 2 threaded pipe connector to connect it to the g...

Страница 9: ...ROPANE NATURAL BUTANE PROPANE NATURAL BUTANE PROPANE NATURAL 28 30 37 20 0 49 0 49 0 72 1 2 1 2 0 8 0 8 0 8 0 6 0 6 0 6 3 0 3 0 3 0 1 75 1 75 1 1 1 1 2 1 75 4 2 6 2 6 2 6 3 8 3 5 3 8 3 5 3 8 3 5 1 0 1...

Страница 10: ...ccording to EN 30 2 1 1998 A1 2003 A2 2005 The semi rapid burner and rapid burner were tested separately the auxiliary burner is not required for test because its nominal heat input is less than 1 16k...

Страница 11: ...nt misuse unauthorised modification or inexpert repair Cost of Call out where a fault cannot be found with the appliance Cost of Call out for work covering routine maintenance such as but not exclusiv...

Страница 12: ...l help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about...

Отзывы: