Place the Fireplace on the platform and install the Vent pipe, and Power Vent module. Next, connect the Gas line, and provide a gas service
shut-off valve; according to local gas codes. Before fastening in place line up the front face of the fireplace (top and bottom
Figure 4
). then
secure in place with 1/4"bolts and washers to the platform.
Figure 4.
Fireplace installation,
(Inlet Gas & Power Vent).
Installing the Fireplace:
1/2”
Supply Gas
connection
Intake / Exhaust
Vent Pipe (5”/10”)
2” Clearance
2” Clearance
Note:
Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
R520 Power Vent Indoor Gas Fireplace
Page 10
XG0771 - 150204
Installation