background image

Page 8

Proflame 2 Transmitter

XG0677 -  141231

Maintenance

Remote Control

When the Remote Control batteries are low, a Battery 

Icon will appear on the LCD display of the Remote 

Control, see 

figure 16

, before all battery power is lost. 

When the batteries are replaced this icon will disappear. 

Figure 16.

  Low Battery Power Detection

Control Module 

(Not applicable for Power Vented Units)

When the Control Module batteries are low, a "double-

beep" will be emitted from the IFC when it receivers 

an On/Off command from the Remote Control. This is 

an alert for a low battery condition of the receiver and 

after that no more command will be accepted. When the 

batteries are replaced the "beep" will be emitted from the 

receiver as soon as powered. 

  Low Battery Power Detection

The life span of the batteries depends on various factors: 

quality of the batteries used, the number of ignitions 

of the appliance, the number of changes to the room 

thermostat set point, etc. 

Problem

Solution

Control  module  beeps 

twice when On/Off button 

on remote is pressed and 

Red LED is On.

Replace  batteries  in  battery 

pack. 

(Not applicable for Power Vented Units)

Lights  and  Fans  will  not 

turn On. 

Check main power is On. 

Pilot will not spark.

Check and turn main On/Off 

switch to On. 

Main burner will not light.  Check wiring

Troubleshooting: 
Below is a list of possible problems and solutions.

Содержание Proflame 2

Страница 1: ...ded for any length of time CAUTION Turn OFF the main gas supply of the appliance during installation or maintenance of the receiver device Turn OFF main gas supply to the appliance prior to removing ro reinserting the batteries In case of remote control malfunction turn OFF the IFC device using the On Off main switch For installation maintenance switch OFF the IFC device by removing main power sup...

Страница 2: ...r uses a streamline design with a simple button layout and informative LCD display see figure 1 A Mode Key is provided to index between the features and a Thermostat Key is used to turn On Off or index through Thermostat functions see figure 1 3 Additionally a Key Lock feature is provided see figure 15 The Proflame 2 System consists of the following elements 1 Pilot Assembly 2 Proflame Gas Valve 3...

Страница 3: ...on Figure 1 Proflame Remote Control Figure 2 Proflame Control Module SW1 LED1 LED2 SW1 Programing Button LED1 Red Diagnostic Light LED2 Amber Programing Remote Control Light Blue Back lit LCD display On Off Key Thermostat Key Up Down Arrow Key Mode Key ...

Страница 4: ...mes and amber LED see figure 2 is illuminated to indicate that the IFC is ready to synchronize with a remote control within 10 sec Push the ON button The control module will beep four 4 times to indicate transmitter s command is accepted The System is now initialized Figure 4a Remote control battery compartment Battery operated device Read the battery instructions before installing them WARNING in...

Страница 5: ...f the command Turn Off the Fireplace With the system On press the On Off Key on the Remote Control The Remote Control LCD display will only show the room temperature see figure 7 At the same time the Control Module will turn off the fireplace A single beep from the Receiver confirms reception of the command Figure 7 Remote Control display Remote Flame Control The proflame has six 6 flame levels Wi...

Страница 6: ...ol icon see figure 12 Use the Up Down Arrow Keys see figure 1 to turn on off or adjust the fan speed see figure 12 A single beep will confirm reception of the command Figure 12 Fan Speed Control Accent Light Control The fireplace may be equipped with accent lights The auxiliary function controls the Accent Lights To activate this function use the Mode Key see figure 1 to index to the AUX icon see ...

Страница 7: ...tinuous Pilot Ignition mode CPI Pressing the Down Arrow Key will return to IPI A single beep will confirm the reception of the command NOTE Requires CPI switch not supplied Set the CPI IPI switch to CPI position Switch closed to enable remote CPI IPI operation Set the CPI IPI switch to IPI position switch open to disable remote CPI IPI operation The system will now work in IPI mode only regardless...

Страница 8: ...of the receiver and after that no more command will be accepted When the batteries are replaced the beep will be emitted from the receiver as soon as powered Low Battery Power Detection The life span of the batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the room thermostat set point etc Problem Solution Control m...

Страница 9: ...Page 9 P52DF Indoor Gas Fireplace XG0196 141231 Notes ...

Страница 10: ...XG0196 141231 Proflame 2 System ...

Отзывы: