Page 17
XG0219 - 080421
Installation
Figure 29
Control box mounting
Control Box Install
Installations in Canada must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70.
Note: If any of the original wire supplied with the appliance is replaced,
it must be with the same it's equivalent.
Connect a 3-Conductor outdoor rated cable from the control box wire
marked "to blowers in fireplace" to the 3 wires on the right side of the
fireplace.
The control box must be mounted in the orientation shown above with
the wires descending from the bottom to minimize the potential for
water ingress.
Wiring
A qualified electrician must install the wiring. The unit is supplied
with an external electrical control box pre-wired by the factory. The
control box is connected to the fireplace with a control cable that will
communicate with the fireplace. The control box should be located
where it can be accessed when the fireplace has been finished in.
USE #8
SCREWS FOR
MOUNTING
Figure 30
Wires to Blowers
Ensure the wires are properly isolated from metal parts or control
system will be damaged.
CAUTION
Use #8 screws for
mounting
Use #8 screws for
mounting
Mounting the Fireplace Control Box
Install the Fireplace Control Box in an accessible location within 3' of
the fireplace. The location should be where maintenance, adjustments
and service may be made easily.
Mount the control box with 4 #8 screws (not supplied) and seal with
an outdoor rated sealant.