background image

P/N XG0207

Page 4

M40DV-ST See-Thru Gas Fireplace

Installation

Installing The Fireplace Shell

The fireplace may be installed in any location that maintains clear-
ances to air conditioning ducts, electrical wiring and plumbing. Safety, 
as well as efficiency of operation, must be considered when selecting 
the fireplace location. Try to select a location that does not interfere 
with room traffic, has adequate ventilation, and offers an accessible 
pathway for Direct Vent installation.
The fireplace dimensions are shown below:

Figure 1.  Fireplace dimensions.

Framing

Unprotected combustible walls which are perpendicular to the 
fireplace opening, must not project beyond the shaded area shown in 
Figure 20b.
For protection against freezing temperatures, it is recommended that 
outer walls of the chase be insulated with a vapour barrier. This will 

Figure 2a.  Framing dimensions for the rough opening.

Clearances

The 

M40DV-ST 

clearances to combustible materials are:

 

Top* 

8"

 

Ends 

1½"

 

Floor 

Combustible

 

Mantle** 

6"

 

Flue Cover 

1 1/2"

*  Clearance from the top of the fireplace to 

a combustible ceiling within the fireplace 
enclosure.

**  Refer to page12.

Figure 2b.  Back-framing to finish enclosing the fireplace can be 

constructed on either the left or right side.

 

End View 

 

 

       Top View

 

Front View

Figure 2c.  Flue Cover clearances to combustibles when installing the 

unit in a top vent configuration.

WARNING!

When this appliance is installed directly on carpeting, tile or any 
combustible material other than wood flooring, it must be installed 
on a metal or wood panel extending the full width and depth of 
the appliance.

Содержание M40DV-ST

Страница 1: ... this manual with the appliance Consumer Leave this man ual for future reference Check local codes and read all instructions prior to installation C US WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistanceoradditionalinformation consultaqualifiedinstaller service agency or the gas supplier Safety Notice Gl...

Страница 2: ...NGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Used to address practices not related to personal injury Important Used to address practices ...

Страница 3: ...bility for the following actions Modification of the fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation require ments for factory built gas fireplaces ...

Страница 4: ...wn in Figure 20b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will Figure 2a Framing dimensions for the rough opening Clearances The M40DV ST clearances to combustible materials are Top 8 Ends 1 Floor Combustible Mantle 6 Flue Cover 1 1 2 Clearance from the top of the fireplace to a combustible ceiling within t...

Страница 5: ... piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Installation Vent Installation This section covers the installati...

Страница 6: ...rews 12 12 MSR Figure 4b Installing a PT0 3 termination with the MSR frame Figure 4c Installing a PT0 3 termination with the MOSR frame 12 12 12 MOSR Installing Terminations with MOSR Frames 1 Frame the termination opening to 12 x 12 2 Fasten the MSR frame to the interior side of the studs using a minimum of 4 screws 3 Insert the termination into the MSR frame as shown here and attach by screwing ...

Страница 7: ...ple B Acceptable Installation If the vertical dimension from the hearth is 72 and the horizontal run to the wall flange of the vent termination is 36 this would be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 48 and the horizontal run to the wall flange of the vent termination is 108 this would not be an acceptable inst...

Страница 8: ...rizontal installation Figure9 Extendedhorizontalinstallationusingacombinationofrigid and flex venting Figure8 HeatShieldforshorthorizontalinstallation Installbysliding overtheventpipewhereitconnectstothetermination Heat Shields Due to high flue temperatures the heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects to the terminatio...

Страница 9: ...e of at least 2 2 Offset Vertical Installations Amaximumoftwooffsets eachoffsethastwo90 bends maybe made if the length of the offsets does not exceed 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 30 vertical vent 2 2 offsets required 25 of 30 7 1 2 max offset allowed This venting configuration meets requirements Figure11b Verticalventingw...

Страница 10: ... flange of the vent termination is 120 this would be an acceptable installation Example B Acceptable Installation If the vertical dimension from the hearth is 66 and the horizontal run to the wall flange of the vent termination is 30 this would be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 48 and the horizontal run to...

Страница 11: ...ve foot chase allow for a maxi mum horizontal run of twelve and one half feet from the centre of the fireplace to outside wall and a minimum of 7 6 when retracted in opposite direction See Figure 14a and 14b D flex sections and E solid sections may be used in conjunction with one another to obtain different possible horizontal length instal lations NOTE Flex section must not exceed maximum horizon...

Страница 12: ... made if the length of the offsets does not exceed 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 30 vertical vent 2 2 offsets required 25 of 30 7 1 2 max offset allowed This venting configuration meets requirements A Termination PVTK 1 B Flex sections PFL 1 12 section PFL 2 24 section PFL 3 36 section PFL 4 48 section C Solid sections PEX...

Страница 13: ...peratures over the mantel will rise above normal room temperature and walls above fireplace may be hot to touch We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or pictures This can cause melt ing deformation discoloration or premature failure of T V and radio components Painting Figure 2...

Страница 14: ...eywellgascontrol and pilot M40DV ST I Removing the Doors To remove the inner doors simply unscrew the eight 8 machine screws on the top and bottom of the door See figure 22c Door Installation To re install the doors align the door with the screw holes and re fasten with all eight machine screws Ensure that a good seal is maintained Re install the side panels and louvre assemblies by reversing the ...

Страница 15: ...plied with five 5 fibre logs The two large bottom logs logs A and B are mounted on the burner grate by placing them into the slots Top Logs Place logs C and D into their mating positions on the large logs as shown in Figure 23a below Log E is mounted on top of logs C and D as shown in Figure 23b Warning If logs are not placed properly excessive sooting will result Installing the Ember Material The...

Страница 16: ... Operation Model M40DV ST 3 Push in gas control knob slightly and turn clock wise to Off Do not force 4 Flip up the lower end louvres 1 Turn off remote switch 2 Flip down the lower end louvres 1 STOP Read the safety information above on this label 2 Flip down the lower louvres on the end panel of the fireplace 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out ...

Страница 17: ...floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower end louvres Gas Inlet Gas Control Switch Shown ...

Страница 18: ...u Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trims 3 Turn the incoming gas control valve to Off 4 Flip UP the lower trims 1 STOP Read the safety information above on this label 2 F...

Страница 19: ... page 13 Handle the door carefully and clean it with an approved glass cleaner One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leav ing a visual deposit of on combustion chamber walls This can easily be removed by following the steps described below Use a vacuum cleaner or soft bristle brush to keep the control compartment burner and fi...

Страница 20: ...ol valve Flame is decreased by turning adjustment screw clockwise Pilot won t ignite Disconnect remote wires and try to light pilot If pilot now works remote connections are faulty Check wiring diagram figure 17 Main burner will 1 Check wiring see figure 17 not light 2 Check wall switch for proper con nection 3 Check pilot burner If extinguished a Allow fireplace to cool then try to relight b If c...

Страница 21: ...rious safety hazards may result in the denial of certification by recognized national safety agencies and could be in violation of local building codes This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning con...

Страница 22: ... in the United States 6 feet 1 8 m minimum in Canada L clearance to nonmechanical air supply inlet to building or the combus tion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance un...

Страница 23: ...anufactured or mobile home The standard M40DV ST or the M40DV ST I equipped with Hot Surface Ignition HSI are not approved for use in mobile or manufactured homes The M40DV ST MH is rated for Natural Gas at 30 000 BTU H 8 79 Kilowatts max input and 24 000 BTU H 7 03 Kilowatts min input Propane at 30 000 BTU H 8 79 Kilowatts max input and 24 000 BTU H 7 03 Kilowatts min input Conversion Kits The M4...

Страница 24: ...y in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection...

Страница 25: ...Page 25 P N XG0207 M40DV ST See Thru Gas Fireplace Notes ...

Страница 26: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0208 02408 ...

Отзывы: