P/N XG0207
Page 18
M40DV-ST See-Thru Gas Fireplace
with Proflame SIT Electronic Ignition
Operation - Model M40DV-ST-F
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
WARNING:
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
To Turn Off Gas To Appliance:
Lighting Instructions:
If you cannot reach your gas supplier, call the
Fire Department.
C.
Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, don't try to repair it,
call a qualified service technician. Force or at-
tempt to repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been
under water. Immediately call a qualified serv-
ice technician to inspect the appliance and to
replace any part of the control system, and any
gas control which has been under water.
A.
This appliance is equipped with an ignition sys-
tem that lights the pilot burner automatically.
Do
not attempt to light the pilot by hand.
B. BEFORE LIGHTING
smell all around the appli-
ance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
1.
Turn off remote switch.
2.
Flip down the lower trims.
3.
Turn the incoming gas control valve to "Off".
4.
Flip UP the lower trims.
1.
STOP!
Read the safety information above on
this label.
2.
Flip down the lower trims.
3.
Turn Incoming gas valve to the ON" position.
4.
Wait 5 minutes to clear out any gas. If you smell
gas,
STOP!
Follow "B" in the safety information
above on this label. If you don't smell gas, go to
the next step.
5.
Turn wall switch "ON".
6
. If the Fireplace does not light, the System will cy-
cle through two trials, (one minute audible click-
ing, thirty seconds of silence, and then another
one minute of audible clicking). If the system
locks out due to inadequate gas flow, refer to
"Troubleshooting", Page 20.
7.
After completion of the information in the Trou-
bleshooting section, Repeat step 5.
8.
If the system will not function correctly, follow the
instructions "To Turn Off Gas To Appliance" and
call your service technician or gas supplier.
EV1 (Pilot
burner)
EV2 (Main
burner)
Pilot Adjust Screw
Lockout Reset Key
Diagnostic Terminal
Power
Command (Wall
switch)
Pilot Sensor
Igniter
Ground
EV1 (Pilot burner)
EV2 (Main burner)
Gas "Out"
Gas "In"
Incoming Gas
Line, Shut-off
Valve
To fireplace
Main burner
M40DV-ST-F
with Proflame SIT Electronic Ignition