Page
P/N XG0202
M38DV-PFC Peninsula Gas Fireplace
Installation
Wiring
115/1/60 Supply
G
L1 L2
Figure 15b.
Fan wiring schematic.
Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fuse
Limit
Switch
Wall
Switch
Fan Plug
Receptacle
Junction Box
Junction Box Cover
White
Black
Green
40 VA
Transformer
115VAC
24VAC
Grnd Screw
Figure 14.
Wiring for the M38DV-PFC-I with Honeywell gas control
and pilot.
Figure 15a.
Fan wiring.
NOTE:
If any of the original wire supplied with the appli-
ance is replaced, it must be replaced with the same
type, or its equivalent.
Fan Wiring
The M38DV-PFC is equipped with 3 fans for circulating heat into the
living space.
Installations in Canada
must be in accordance with
CSA C22.1
Canadian Electrical Code Part 1 and/or Local Codes.
Installations in the USA
must be in accordance with local codes
or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
G
L1-WH
L2-BLK
Quick Connect
plug to motor
Fan Switch
Fan Switch
Fan
Motors
(3)
M38DV-PFC-I
Figure 16b.
Completed Installation.
Figure 16a.
Log Installation.
Installing the Logs and Embers
Bottom Logs
The
M38DV-PFC
is supplied with five (5) fibre logs. The two large
bottom logs (logs
"A"
and
"B")
are mounted on the burner grate by
placing them into the slots.
Top Logs
Place logs
"C"
and
"D"
into their mating positions on the large logs as
shown in Figure 16a below
.
Log
"E"
is mounted on top of logs
"C"
and
"D"
as shown in Figure 16b.
WARNING: If logs are not placed properly, excessive