31
Operation
XG0229 - 112718
Inlet Pressure
Test Connection
Pilot Adjustment Screw
Manifold Pressure
Test Connection
To Turn Off Gas To Appliance:
3. Turn the incoming gas control valve to "Off".
4. Replace the lower Horizontal access panel.
1. Turn off fireplace using wall switch or remote control.
2. Remove the lower Horizontal access panel.
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
6. Turn fireplace "ON" using wall switch or remote control.
7. If the Fireplace does not light, the System will cycle through two trials, (one
minute audible clicking, thirty seconds of silence, and then another one
minute of audible clicking). If the system locks out due to inadequate gas
flow, refer to "Troubleshooting" in instruction guide.
8. After completion of the information in the Troubleshooting section, Repeat
step 5.
9. If the system will not function correctly, follow the instructions "To Turn Off
Gas To Appliance" and call your service technician or gas supplier.
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn "ON" manual "ON/OFF" switch located below the horizontal access
panel (if available).
4. Turn Incoming gas valve to the ON" position.
5. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Follow "B" in the
safety information above on this label. If you don't smell gas, go to the next
step.
SIT Proflame 2 Electronic Ignition
LED1
LED2
Power
SW1
Stepper
motor
Main
harness
Main
On/Off
Switch
Switch
sensor
Ignitor
3.15A
Fuse
SW1 = Programing Button
LED1 = Red Diagnostic Light
LED2 = Amber Programing Remote Control Light
PILOT ADJUSTMENT SCREW
INLET PRESSURE
MANIFOLD PRESSURE TEST
CONNECTION