f i r e
f e a t u r e
EDVRSPV Vertical Power Vent System
Part No. XG1302 - 101201.2
Installation
Figure 6.
Installation of Rough-in Kit
Step 3.
Install the Power Vent Rough-in Kit. Pull wire harness
through the supplied hole in the bottom corner of the
rough-in box, and snap into the slot provided,
(See figure 6
inset)
.
Electrical Harness
Power Vent
Rough-in Kit
Electrical Harness
Connector Location
Inset
Step 2.
Install the Vent pipe female end up, and 2" to 3" MAX. from
the top of the Constructed Chase. Also, at this point install
the Electrical harness, (EPVH-(10-100) that will communicate
with the Power Vent Module.
Vent Pipe
Vent Chase
Electrical Harness
with Connection
2 to 3” MAX
Figure 5.
Figure 7.
(Fasten Rough-in Kit to framing)
Step 4.
Install fasteners around perimiter of Rough-in Kit.
(Holes sup-
plied for ease of installation)
Install Fasteners around
perimeter of Rough-in Kit
Figure 8.
(Installed Stainless steel cover)
Step 5.
Install the Power Vent, Roof-top Stainless steel cover over
the Installed Rough-in Kit.
(You can see the Electrical harness
connector in the top right corner).
Figure 9. Figure 9a.
Step 6.
Install the Power Vent Module Power / communication
harness. Hold the Power Vent in close proximity of the as
-
sembled Chase, (with stainless steel cover attached) and
plug in the Power Vent communication / Power Cord.
(Note
the direction and orientation of the plug socket). (See Figure 9 &
Figure 9a)
Electrical Harness
from Power Vent
Page 6