  (Gas Fireplace / Equipment sold in the State of Massachusetts)

 

 

 

 

   5.08: Modifications to NFPA-54, Chapter 10

 

(1) Revise NFPA-54 section 10.5.4.2

 

by adding a second exception as follows:

Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset 

device that will automatically shut off the gas to the burner in the event of a sustained back-draft

.

 

(2) Revise 10.8.3 by 

adding the following additional requirements:

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential 

purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above 

finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 

 

1. INSTALLATION OF CARBON MONOXIDE DETECTORS.

 

At the time of installation of the side wall horizontal vented gas fueled equip

-

ment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the 

floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired 

carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal 

vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installa

-

tion of hard wired carbon monoxide detectors

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detec

-

tor with alarm and battery back-up may be installed on the next adjacent floor level.

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) 

days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with 

an alarm shall be installed.

 

2. APPROVED CARBON MONOXIDE DETECTORS.

 

Each carbon monoxide detector as required in accordance with the above provisions 

shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 

 

3. SIGNAGE. 

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall 

read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation un

-

less, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 

through 4. 

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 

 

1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the 

Board; and 

 

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 

structure used in whole or in part for residential purposes.  

 

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED

. When the manufacturer of Product Ap-

proved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instruc

-

tions provided by the manufacturer for installation of the equipment and the venting system shall include:

 

1. Detailed instructions for the installation of the venting system design or the venting system components; and

 

2. A complete parts list for the venting system design or venting system. 

 

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED

. When the manufacturer of a Product 

Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting sys

-

tems”, the following requirements shall be satisfied by the manufacturer:

 

1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 

 

2. The “special venting systems”

 shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 

detailed installation instructions. 

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts 

lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

 

(3) After NFPA-54 section 10.10.4.2

 add a new section 10.10.4.3 as follows:

When more than four gas appliances are to be vented through a common gas vent or common horizontal vent manifold, a plan of the proposed vent 

installation shall be submitted to the Inspector and the serving gas supplier for review and approval.

Extraction from: Massachusets Rules and Regulations

5.00: Amendments To 2002 Edition Of ANSI Z223.1-NFPA-54

Appendix B - State of Massachusetts

Page 11

Содержание EDVRSPV Series

Страница 1: ...ll times Warning Improperinstallation adjustment alteration serviceormaintenancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified ins...

Страница 2: ...to address practices not related to personal injury Table Of Contents Important All dimensions and design specifications are subject to approval upon quotation of fire place and associated equipment C...

Страница 3: ...securely fastened and sealed to the flex pipe Fasten the termination to exterior of the building with water tight sealant and the appropriate fasteners General Information This installation guide cove...

Страница 4: ...f i r e f e a t u r e EDVRSPV Vertical Power Vent System Part No XG1302 101201 2 Installation Unit Dimensions Figure 1 EDVRPSV58 Dimensions Figure 1 EDVRPSV Page 4...

Страница 5: ...enting Installations Multi Elbow Installations Multi elbow installations are possible up to a maximum of six 90 elbows V Restrictor 1 Max V Max Elbows 100 feet six 90 Elbow 1 Elbow 2 Elbow 3 Elbow 5 E...

Страница 6: ...Vent Chase Electrical Harness with Connection 2 to 3 MAX Figure 5 Figure 7 Fasten Rough in Kit to framing Step 4 Install fasteners around perimiter of Rough in Kit Holes sup plied for ease of install...

Страница 7: ...stallation of Power Vent Module Figure 11 Installed Power Vent Module Step 8 Install 3 three stainless steel fasteners around Power Vent Module 120 degrees penetrating through the inner stain less ste...

Страница 8: ...em Part No XG1302 101201 2 Installation WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life Figure 13 Standar...

Страница 9: ...ected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce...

Страница 10: ...A I N A J N A K N A L N A M N A N N A P N A Q Clearance above a roof 24 inches 61 cm minimum Follow Local Codes R Clearance to adjacent walls and neighboring buildings 16 inches 46 cm minimum S N A T...

Страница 11: ...de directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VE...

Страница 12: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG1302 101201 2 f i r e f e a t u r e...

Отзывы: