Installation
Vertical Termination - 2 Elbows
Vertical Termination
Vertical Termination - 2 Elbows
Vertical Termination
Figure 8.
Vertical Termination
Figure 8.b
Vertical Termination - 2 Elbows
*Restrictor may be required
If the vent rise is over 8ft straight vertical, a restrictor must be installed.
We recommend using the 1.75” wide restrictor. If 1.75'' is too restrictive,
a 1.5'' and 1'' restrictor is also supplied.
NOTE:
If using a restrictor, use an IR gun to measure the glass
temperature after 1 hour of running, and ensure the glass temperature
does not exceed 470°F and ensure that none of the media and no part
of the door has discoloured.
*Minimum 36'' from top of unit before attaching an elbow
V1
V1
H1
V2
Section 3-3-1: Venting Layouts
D3615, D3615ST, D4215, D4215ST, D7215, D7215ST
Vertical Minimum V1+V2
3'
4'
5'
6'
7'
8'
9'
10'
Horizontal Maximum H1
2'
6'
10'
12'
15'
18'
21'
24'
D3615, D3615ST, D4215, D4215ST, D7215, D7215ST
Vertical Minimum
3'
Vertical Maximum
32'