Installation
Figure 10
Gas and electrical
Electrical Requirements
Gas supply requirements
Electrical Cover
Plate
SCREEN
WINDOW
BURNER TRAY
BURNER ASSY
FANS
LED ASSY
VACUUM SWITCH
ASSY
VACUUM TUBING
ASSY
MAIN ASSY
1:8
SIZE DWG. NO.
A
REV.
SHEET 1 OF 2
WEIGHT:
P42VFO
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CHECKED BY
DRAWN BY
TMC
DATE
NAME
A
28-Jul-16
P42 Vent Free - OD
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\PL42VO\Cad Drawin
gs\TMC April 2016 Revision with Rick\P42VFO
November-15-16 9:37:02 AM
SCALE
Figure 11
Electrical Plate location
Gas Shut off
Valve (supplied)
Remote
Control Box
On/Off Toggle
Switch and fan
speed switch
6 conductor cable 30ft supplied by Montigo
3 conductor outdoor power cable 16AWG
(not supplied)
3 conductor
cable (supplied)
3 conductor
cable
(supplied)
Power Outlet
with GFCI
Gas Line
The fireplace is supplied with a waterproof control box which may be
mounted to an outside wall and a 3 foot powercord. A GFCI protected
plug to plugin the control box is required within 3 feet of the control box.
Electrical Requirement for Control Box: 120VAC, 60 Hz, 5 A. GFCI
protected plug required.
30 foot communication cable is supplied with the fireplace to connect
the control box to the fireplace.
3 conductor (Live, Neutral, and Ground) outdoor rated cable must be
supplied by the installer to provide 120VAC power from the control box
to the Fireplace (see figure below).
The optional Fireplace remote control comes in a separate water tight
box and can be mounted to the outside wall close to the fireplace control
box and needs to be wired to the control box using a 3-conductor
outdoor rated cable (supplied).
Have a certified gas fitter install a gas line that will supply the required
level of gas to the left side of this fireplace with an accessible gas service
shut of valve. (shut off valve supplied)
Montigo requires a service shut off valve be located in an accessible
location to isolate the gas supply.
Only install gas shut-off valves supplied or approved for use by the
state, province, or other governing body in which the fireplace is being
installed.
Flexible gas connectors must not exceed 3 feet in length, unless
allowable within local regulations.
Connect incoming gas line to the 1/2"or 3/8" gas inlet port.
Keep the hose out of pathways where people may trip over it or in areas
where the hose may be subject to accidental damage
Figure 12
Gas connection
GAS PRESSURE
• Optimum appliance
performance requires proper
input pressures.
• Gas line sizing requirements
will be determined in ANSI
Z221.3 National Fuel Gas
Code in the USA and CAN/
CGA B149 in Canada.
Pressure requirements are:
Gas Pressure
Natural Gas
Propane
Minimum inlet
pressure
5.5in. w.c.
11in. w.c.
Manifold pressure
3.5in. w.c.
10in. w.c.