BF36 SS and ST Gas Fireplace

Part No. XG0712 - 031811

f i r e    f e a t u r e 

Warning:

 

Read this manual before installing, operating or troubleshooting this ap-

pliance. Please retain this owner's manual for future reference.

     

Safety Alert Key:

• DANGER!

  Indicates a hazardous situation which, if not avoided will result in death or serious injury.

• WARNING! 

Indicates a hazardous situation which, if not avoided could result in death or serious injury.

• CAUTION! 

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

• NOTICE: 

Used to address practices not related to personal injury.

  

Important: 

Used to address practices not related to personal injury.

Table Of Contents

Congratulations

Congratulations on selecting a FireFeature Custom gas fireplace, an 

elegant and well designed gas fireplace built to your specifications. 

The Firefeature gas fireplace you have selected is designed to pro-

vide the utmost in safety, reliability, and engineering standards. 
As the owner of this new fireplace, you'll want to read and carefully 

follow all the instructions contained in this Installation, Operations and 

Maintenance manual. Pay special attention to all cautions, warnings, 

and Important warnings.
 

This owner's manual should be retained for future reference. We 

suggest that you keep it with all your other important documents and 

product manuals.
The information contained in this owner's manual, unless noted other-

wise, applies to all models, and gas control systems.
Your new FireFeature Custom gas fireplace will give you years of 

durable, reliable use. Welcome to the FireFeature  family of gas 

fireplace products.

Congratulations
Safety Alert Key
Introduction

 ............................................................................... 3

Installation

 

Installing and Framing the Fireplace .............................. 4

 

Installing the Gasline ...................................................... 5

 

 

Installation Requirements .................................. 5

 

 

Electrical Supply ................................................ 6

                         Installing the Remote Switch ............................. 6
 

 

Vent Terminations .............................................. 6

 

 

Venting ............................................................... 6

 

Power Vent Control Box ................................................. 7

 

Start-Up Sequence schematic ....................................... 8

 

Removing & reinstall the Door ....................................... 9

 

Installing the BF36 Logset............................................ 10

 

Installing the BF52 Logset............................................ 11

 

Installing the BF60 Logset.....................................12 - 13

 

Installing the BF84 Logset.....................................14 - 15

 

Installing the BFL52 Designer Beads ........................... 14

 

Finishing around the fireplace

 

 

Facing .............................................................. 15

 

             Mantels and Surrounds ................................... 15 

Operation

  .........................................................................16 - 17

 

Start-up Sequence ................................................16 - 17

Maintenance

  ........................................................................... 18

 

General ........................................................................ 18

 

Cleaning ....................................................................... 18

            Troubleshooting ............................................................ 18

Warranty

  ................................................................................. 19

Appendix

 

A  State of Massachusetts / Amendment ..................... 20

Notes 

  .................................................................................... 21

Содержание BF36-SS

Страница 1: ...ion adjustment alteration serviceormaintenancecancauseinjury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor...

Страница 2: ...ions contained in this Installation Operations and Maintenance manual Pay special attention to all cautions warnings and Important warnings This owner s manual should be retained for future reference We suggest that you keep it with all your other important documents and product manuals The information contained in this owner s manual unless noted other wise applies to all models and gas control s...

Страница 3: ... correct vent run and air supply information to the Engineering staff of Montigo After this initial consultation with Montigo we will specify the correct power vent model for your project The fireplace can be installed on any combustible platform as there will be no heat transfer to the base of the fireplace Fresh Air Supply Connect all of the fresh air supply for this fireplace to the lower vent ...

Страница 4: ...oom traffic has adequate ventilation and offers an accessible pathway for vent installation Refer to Vent Installation Section for more information Please refer to the dimensions below and the clearances on the fol lowing pages when selecting the location of your fireplace 35 875 27 875 9 750 39 120 44 000 28 000 34 020 12 000 31 120 66 050 4 520 26 060 7 125 20 340 11 830 35 875 27 875 9 750 39 1...

Страница 5: ...Framing dimensions and clearances to combustibles Framing Single SIded Unit Figure 3 Framing dimensions side view W 108 Y X Z X1 X W 108 Y X Z X1 X Figure 2 Framing dimensions and clearances to combustibles Figure 3 Framing dimensions side view W X X1 Y Z BF 36 SS 94 48 73 64 27 BF 36 ST 94 48 73 64 27 ...

Страница 6: ...ble for test gauge connection immediately upstream of the gas supply controls to the appliance The fireplace gas connection and the main operating gas valve is located behind the removable brick panel in the centre of the unit It only needs to be attached to the gas line with an approved fitting as required by the applicable installation codes The appliance and its individual shutoff valve must be...

Страница 7: ...replace is equipped with a 20 foot low voltage wire for connecting to a wall switch of your choice longer lengths are an option Figure 7 Electrical Supply 110V Power Supply Power Vent Motor Gas Control Wiring Wall Switch Air Proving Switch Fuse Fan Speed Control Post Purge Control Vent Terminations Selecting A Termination Location Before installing the termination or venting check to ensure the pl...

Страница 8: ...atedundertheburners willmonitorthecombustion air supply pressure and will prevent the burner from igniting or continuing to burn if the pressure is negative past 0 08WC For extremely long air supply runs the combustion air supply will have to be power assisted Figure 7b BF SS Standard Control Box Power Vent Control Box Wiring requirements for Power Vent Installation Power Vent Termination Power Ve...

Страница 9: ...mart Valve No 1 as well as terminal 3 and 4 with relay R2 activating Smart Valve No 2 7 The Smart Valve system will light the pilotand by proving the pres ence of a pilot flame it will fire up the burners After the third failure to establish a pilot the valve will lock out 8 To reset the system turn the wall switch off and then back on First Burner 1 2 Black White Second Burner 3 4 Blue Yellow Wal...

Страница 10: ...he 10 24 screws counterclockwise Note Have someone hold the door window assembly in place until all screws are removed Then grab the assembly from either end lifting it away from the fireplace Place it in a safe location to store or clean Figure17 Step4 Removaliscomplete Proceedwithserviceorcleaning installing the door Install the door in reverse order as shown in Steps 1 through 4 Important whenr...

Страница 11: ...ll look like shown in figure 27f Figure 27f Completed Logset Step 2 Place the longest bottom 2 logs length wise on the log grate as shown in figure27a Ensure the charcoal colour is faces down the indents facing up and opposite each other Indents are for positioning the next log see figure 27b Figure 27a Bottom Rear Log Log A Figure 27b Centre log placement Step 3 Place the second longest centre lo...

Страница 12: ...e opening at all because it will interfere with the access to retainers for removal of glass door Figure 14 Combustible mantles and facings W O Door Figure 15 Combustible surrounds Fireplace Facing With Door When selecting the finish material for your fireplace it is important to remember the following The face of the fireplace may be painted to match the room decor provided you use a heat resista...

Страница 13: ...t try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Remove the lower Horizontal access panel 3 Turn the switch on the gas control to Off 4 Replace the lower Horizontal access panel 1 STOP Read the safety information above on...

Страница 14: ...rner and firebox free from dust and lint Logs may be cleaned periodically with a vacuum to remove soot or other contaminates Figure 16 Honeywell SV9501 gas valve Troubleshooting If your fireplace still does not operate correctly consult your dealer or the manufacturer All service and repairs should be performed by a qualified agency All spare parts optional fans and optional trim finishes are avai...

Страница 15: ...be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under ...

Страница 16: ...e grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless ...

Страница 17: ...Page 17 BF36 SS and ST Gas Fireplace Part No XG0712 031811 f i r e f e a t u r e Notes ...

Страница 18: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0712 031811 f i r e f e a t u r e ...