Page 57
XG0526-151109.2
I-Series Indoor Gas Fireplace
Maintenance
Figure 39 Sec.6
7).
Remove the 2 screws securing the pilot bulk head plate and
gasket to the firebox wall. The gasket may be stuck to the wall and
may need to be pried
8).
Remove the screws securing the valve mounting bracket. Swing
valve out. Disconnect the pilot line from the bottom of the gas valve.
Figure 40 Sec.6
9).
Remove the 2 screws securing the top of the control mounting
bracket to the outer shell of the fireplace.
10).
Disconnect both the ignition wire and the flame sensor wire from
the control board.
Figure 41 Sec.6
12).
From the inside of the firebox, pull the pilot assembly, bulk head
plate, gasket and 3 lines through the firebox and out of the unit. Leave
the ground wire in the firebox.
Figure 42 Sec.6
Figure 43 Sec.6
11).
Feed the 2 electrical lines from the control board to the side of
the unit.
Figure 44 Sec.6