Montgomery Ward MW-L3-10C Скачать руководство пользователя страница 4

   7

6

1

888

557

3848

Wards.com      

Installation

Installation 

(cont’d)

After unpacking, dispose of all packing materials in accordance with local ordinances. 

CAUTION:

 Risk of suffocation - keep all packaging and plastic bags out of the 

reach of children.

After all parts are assembled and the portable air conditioner is in an upright 

position on a level, dry surface, wait at least 2 hours before first use.

Install Exhaust Hose

1.  Insert exhaust hose into exhaust outlet and turn counter-clockwise.
2.  Attach adapter to other end of exhaust hose and turn counter-clockwise.

Install Window Frame Adapter

3.  Slide the two parts of the window frame adapter together to form one piece.
4.  Open window and insert window frame adapter.
5.  Extend the window frame adapter so that both ends come in contact with the 

window frame. Fits openings 24

½

 - 52

"

.

6.  Fasten the window frame adapter together with the screws provided.

Install Portable Air Conditioner

1.  Move the unit into place, with the exhaust hose assembly closest to the window 

frame adapter. Keep a 20

"

 clearance around the unit.

2.  Slowly extend the exhaust hose and snap the flat end of the connector into the 

elliptical opening on the window frame adapter. 

3.  Plug power cord into a dedicated, grounded outlet and press the reset button 

on the plug.

4.  Refer to Operating Instructions section prior to powering on the unit.

NOTE:

 Do NOT extend the exhaust hose beyond 59

"

 or have bends in the hose 

greater than 45

°

.

Correct Installation

Incorrect Installation

Important!

 The exhaust hose is made especially for this appliance. Adding or 

replacing a different hose could cause a malfunction with the unit and will void the 

warranty.

Содержание MW-L3-10C

Страница 1: ...5502 115V 60Hz Wards com 1 888 557 3848 Montgomery Ward Customer Service 1112 7th Avenue Monroe WI 53566 8 00 am to Midnight Monday through Friday Wards com 1 888 557 3848 Portable AC 10 000 BTU Energ...

Страница 2: ...or appliance in water or other liquid 7 Use a dedicated circuit to avoid a power surge or overloading of the circuit 8 Do NOT allow water to get on control panel or into any part of the unit 9 Use the...

Страница 3: ...23 Do NOT store flammable or combustible liquids by unit 24 Do NOT step or sit on air conditioner 25 Discard appliance following local ordinances 26 Do NOT use appliance for other than intended use P...

Страница 4: ...window frame adapter so that both ends come in contact with the window frame Fits openings 24 52 6 Fasten the window frame adapter together with the screws provided Install Portable Air Conditioner 1...

Страница 5: ...tton Use this button to designate the number of hours up to 24 the unit should run continuously until automatically shutting down or the number of hours until the unit automatically starts Each press...

Страница 6: ...er and rinse thoroughly Dry frames with soft cloth and let filters dry in the sun Operating Instructions cont d To use the remote control you must be within 20 feet of the unit with a clear line of si...

Страница 7: ...or to lifting unit to prevent spillage Important Do not tilt air conditioner more than 30 to avoid damaging the condenser Troubleshooting Before calling for service try these troubleshooting tips Prob...

Страница 8: ...0 a m to Midnight CT Monday through Friday 17 16 1 888 557 3848 Wards com Wards com 1 888 557 3848 14 15 Montgomery Ward Inc warrants this product to be free from defects in material and workmanship f...

Отзывы: