background image

1

2/30

/2011

© 2011 Monte Carlo Fan Company

5

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Make sure that any shipping stabilizer has been removed from motor.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  DO

NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance

from blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can

adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer

(not supplied) between the blade and blade holder at the screw closest to the motor. To

adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at

the two screws farthest from the motor.  Reverse the position of the washer if blades mount

from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Trouble

Suggested Remedy

Содержание 5WF52 Series

Страница 1: ...L Model No AC 552OD Total fan weight DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 6 8 kgs 14 96 lbs ...

Страница 2: ...nce with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or dur...

Страница 3: ...let box Remove keeper from pin see inset Loosen the 2 set screws in yoke for downrod to slip into yoke 3 2 1 4 6 Thread wires and safety cable through downrod with canopy and yoke cover assembled 5 Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mounting br acket This will allow hands free wiring 8 7 Tighten both yoke set screws t...

Страница 4: ...wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips 11 House Fan Black White Green Black White Green downrod Green Bracket Blue For control of fan and optional light from wall location follow diagram above NOTE A professional electri cian is recommended for this type of installation 12 Light Switch Fan Switch Wall Control...

Страница 5: ...surement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of th...

Страница 6: ...Jan 2012 new format new customer service information Jul 2013 Update for CUL regulation ...

Отзывы: