background image

3

© 2018 Monte Carlo Fan Company

10/2018

1

2

3

4

5

6

ON

OFF

ON

OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally. When the service 

disconnecting means cannot be locked, 

securely fasten a warning device, such  

as a tag, to the service panel.

Use AC 120V/60HZ power supply 

only.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 

lbs). Before attaching fan to outlet box, 

ensure the outlet box is securely fastened 

by at least two points to a structural 

ceiling member ( a loose box will cause 

the fan to wobble). Remove the two outlet 

box screws provided with the box, 

aligning the holes of the mounting 

bracket with the holes of the outlet box. 

Reinstall the 2 outlet box screws 

securely.

Remove shipping stabilizers from motor.

Partially loosen downrod set screws from 

yoke at top of motor assembly.

Remove preassembled cross pin and 

keeper pin from downrod. 

Place downrod over canopy and yoke 

cover. Thread lead wires and safety cable 

from motor assembly through downrod.

Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must 

be installed securely, failure to install them 

will result in serious injury.

Yoke cover

Mounting bracket

Downrod

Cross pin

Cross pin

Keeper pin

Keeper pin

Shipping stabilizer

Canopy

Downrod

Содержание 5VMR72 D Series

Страница 1: ...DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5VMR72XXXD Series Fan cETL Model NO 5VMR72XXXD 9 3 kgs 20 5 lbs ...

Страница 2: ...x to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan should only be used with ...

Страница 3: ...g member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Reinstall the 2 outlet box screws securely Remove shipping stabilizers from motor Partially loosen downrod set screws from yoke at top of motor assembly Remove preassembled cross pin and keeper pin from downrod Place do...

Страница 4: ... from Fan to White Neutral wire from house Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connectors After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splic...

Страница 5: ...llustration Keep screws Install blanking plate onto light plate using the set screws of light shade which were just removed Isolate the quick connects with electrical tape Attach blanking plate assembly onto light pan by locating dimples in light pan with grooves in blanking plate and twist clockwise until tight Attach light pan onto the plate on motor Place light pan over the lead wires from fan ...

Страница 6: ...en off The fan will start to run and begin the control setting process The fan will run in both directions for a total of approximately 3 minutes then the fan will stop The control and speed setting process is complete and the fan is ready for use Note If the power is on already you must turn the power off for at least 5 seconds and then turn the power back for remote control setting The buttons o...

Страница 7: ...and power on it is because your fan is still memorize the previous setting at factory Make Remote control setting learn function and your fan will be ready for use 2 If fan or light isn t working reset power turn the power off for at least 5 seconds and then turn the power back and redo the remote setting 3 It is not available to separately operate the remote setting for more than one fan in the s...

Страница 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat fo...

Страница 9: ...Nov 2018 ...