2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Trouble

Suggested Remedy

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the same

frequency.

CaUTION:  Make sure main power is turned off

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CaUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is posi-

tioned for measurement. Repeat for each blade. If all blade levels are not equal, you can

adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer

(not supplied) between the blade and blade holder at the screw closest to the motor. To

adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at the

two screws farthest from the motor.  Reverse the position of the washer if blades mount from

top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CaUTION:  Make sure main power is turned off before entering switch housing. 

Customer Service Center:

301 West Washington St.

Riverside, NJ 08075 

1-800-519-4092

www.montecarlofans.com

Содержание 5TV52XXD Series

Страница 1: ...liente Si vous avez besoin d aide pour l installation des pièces de remplacement ou si vous avez des questions concernant notre garantie veuillez contacter notre service après vente If you need installation assistance replacement parts or have questions regarding our warranty please call our customer care center NEED HELP NECESITA AYUDA AVEZ VOUS BESOIN D AIDE Please do not return this product to ...

Страница 2: ...hower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment man ufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the Americ...

Страница 3: ...Check the motor for shipping stabi lizers and remove if present Attach blades using screws and washers in hardware pak Tighten screws securely 13 Loosen 2 screws and remove 1 screw from motor plate Save removed screw for use later 14 Connect plug from fan to switch house plug 16 Install by twisting clockwise add 1 screw removed step 14 to switch housing plate Tighten the 3 screws securely 15 Conne...

Страница 4: ...e grooves in the non light kit cover and twist clockwise till tight WaRNING Make sure light bulb is not installed when using this cover 22 Install 75 watt halogen bulb Do not touch bulb surface as oily residue from skin can cause the bulb to explode Bulb Included WaRNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the light...

Страница 5: ...le speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy...