background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and

pushed carefully up into the outlet box.

WaRNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to

the trailing edge of the blade.

WaRNING

: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting

screws provided with the outlet box  (Mounting must support at least 35 lbs.)

WaRNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert for-

eign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WaRNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WaRNING

: To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment man-

ufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,

Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CaUTION: 

To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

afETy

T

IpS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

1

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

2

Thread safety cable through center

hole of the mounting plate. Thread

your house wires through center hole

also.These will be needed for wiring

of the fan.

4

Securely attached the mounting

plate to the outlet box using two

screws supplied by the outlet box.

Use metal outlet box suitable for

fan support (must support 35

lbs).

6

Place the decorative ring on the

motor housing.

3

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod mode the safety cable must be

installed into the house structure beams using

the 3” lag screws provided.  Make sure that

when the safety cable is fully extended the

leadwires are longer than the cable and no

stress is placed on the leadwires.

5

Safety cable installation

Safety Cable

Lag Screw

Lag Screw

Safety Cable

Washer

Lock Washer

Содержание 5TV52XXD Series

Страница 1: ...liente Si vous avez besoin d aide pour l installation des pièces de remplacement ou si vous avez des questions concernant notre garantie veuillez contacter notre service après vente If you need installation assistance replacement parts or have questions regarding our warranty please call our customer care center NEED HELP NECESITA AYUDA AVEZ VOUS BESOIN D AIDE Please do not return this product to ...

Страница 2: ...hower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment man ufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the Americ...

Страница 3: ...Check the motor for shipping stabi lizers and remove if present Attach blades using screws and washers in hardware pak Tighten screws securely 13 Loosen 2 screws and remove 1 screw from motor plate Save removed screw for use later 14 Connect plug from fan to switch house plug 16 Install by twisting clockwise add 1 screw removed step 14 to switch housing plate Tighten the 3 screws securely 15 Conne...

Страница 4: ...e grooves in the non light kit cover and twist clockwise till tight WaRNING Make sure light bulb is not installed when using this cover 22 Install 75 watt halogen bulb Do not touch bulb surface as oily residue from skin can cause the bulb to explode Bulb Included WaRNING Over lamping the fan will result in the fan lights shutting down until the proper wattage of bulbs are installed Reset the light...

Страница 5: ...le speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy...

Страница 6: ...Apr 7 10 issued ...

Отзывы: