1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the same

frequency.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other

or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering the switch housing

and/or the canopy.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT

USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned

for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade

levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied)

between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up,

insert washer (not supplied) between the blade and blade holder at the two screws farthest from

the motor.  Reverse the position of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redis-

tribute the weight and possibly result in smoother operation.

1.Check wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

WARNING: Over lamping the fan will result in the fan lights shutting down

until the proper wattage of bulbs are installed.

Reset the lights by turning off the wall switch, breaker,or by remote. Replace bulbs

with the correct wattage bulbs, turn the power on.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds

noisy:

1. If fan does not

start:

3. If fan wobbles:

4. If light does not

work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Trouble

Suggested Remedy

Содержание 5SBR56XXD-L Series

Страница 1: ...rd and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5SBR56XXD L Series Fan Total fan weight with light kit UL Model No AC 556LF4000 18 5 kgs 40 7 lbs ...

Страница 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Страница 3: ...ety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws 3 Remove the 6 screws attaching the Mounting neck the mounting plate Retain the 6 screws for re assembly 4 Loosen 2 screws and remove gate Save gate for use later 9 Lift mounting neck to mounting Plate and align screws 7 Secure mounting neck to the mount ing plate with 6 screws to become a complete ...

Страница 4: ...an not feel screws on inside of yoke 10 15 12 13 Use 3 screws removed to attach arch brackets to arch hub 11 14 Slide canopy ball arch assembly and yoke cover over downrod Thread lead wires and safety cable through downrod as shown Remove keeper from cross pin and then cross pin from yoke Replace keeper on cross pin and save Align hole in downrod with hole in yoke and install cross pin Install dow...

Страница 5: ... Install remote receiver by sliding into opening in the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 39 for remote operation 22 white black Make wiring connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked ...

Страница 6: ... breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on Lift light kit to the fan motor assembly Align the 3 screws with the key hole slot holes in the light kit see inset Rotate the light kit as shown Then install the screw removed in the previous step though the closed hole Tighten all 3 screws securely 32 33 Twist light kit into place by turning direction of arrow 3...

Страница 7: ... remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snaping into place 37 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 38 Attach front cover to wall control with screws provided Snap battery cover in place 39 WALL MOUNT INSTALL ...

Страница 8: ...light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fan must be running to reverse UPLIGHT ON OFF S...

Страница 9: ... following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two ...

Страница 10: ...REV 1 2 4 04 Step 8 in safety tips step 2 page 2 battery remote ...

Отзывы: