Before you begin installing the fan, Switch
power off at Service panel and lock service dis-
connecting means to prevent power from being
switched on accidentally. When the service dis-
connecting means cannot be locked, securely
fasten a prominent warning device, such as a
tag, to the service panel.
Warning
-Risk of fire, electric shock, or person-
al injury. The fan in this box may be either
directly supported from a structural framing
member of a building and/or may be mounted
to an outlet box marked acceptable for fan sup-
port of of 31.8 kg (70 lbs) or less. Most outlet
boxes commonly used for the support of lummi-
naires may not be acceptable for fan support
and may need to be replaced. Consult a quali-
fied electrician if in doubt.
2
1
OUTLET BOX METHOD
Remove Safety bar from mounting bracket by
loosing screws, sliding bar to side, and lifting it
off the 2 screws.
3
Remove the
6
screws attaching the Mounting
neck the mounting plate. Retain the
6
screws
for re-assembly.
4
Loosen 2 screws and remove gate.
Save gate for use later.
9
Lift mounting neck to mounting Plate
and align screws.
7
Secure mounting neck to the mount-
ing plate with
6
screws to become
a complete mounting bracket.
8
Secure mounting plate directly to a joist from
the buliding structure via the two knock out
holes on the outlet box. Use only the appropri-
ate wood screws and washers included with
your fan.
Caution
: Wood screws must go through into
the building joist.
Note
:If Installing It In The U.S., Do Not Re-
move Knockouts In The Outlet Box
5
Outlet box
Mounting
Plate
Wood
Screws
BUILDING STRUCTURE METHOD
Install the mounting Plate to approved fan
brace and box combination use only the hard-
ware provided with the fan brace and box.
6
FAN BRACE AND OUTLET BOX METHOD
For Installation in The U.S. only