background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the

same frequency.

CAUTION:  Make sure main power is turned off.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each

other or against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear

after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box

and junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by

selecting a point on the ceiling above the tip of one of the blades. Measure the distance

from blade to ceiling. Keeping measure within 1/8", rotate the fan until the next blade is

positioned for measurement. Repeat for each blade. If all blade levels are not equal, you can

adjust blade levels by the following procedure. To adjust a blade tip down, insert a washer

(not supplied) between the blade and blade holder at the screw closest to the motor. To

adjust a blade tip up, insert washer (not supplied) between the blade and blade holder at

the two screws farthest from the motor.  Reverse the position of the washer if blades mount

from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can

redistribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

WARNING: Before attempting to replace the fuse make sure the main power is

turned off to the fan. Replace only with 3 amp fuse. Fuses located in canopy.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

Trouble Shooting

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation,

or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults,

please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty

in installation, please call our Customer Service Center at the number printed on your parts list insert sheet.

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service dis-

connecting means to prevent power from being switched on accidentally.  When the service dis-

connecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,

to the service panel.

Customer Service Center:

740 S.W. Loop 820, Suite 110

Fort Worth, Texas 76115

1-800-519-4092

Suggested Remedy

Trouble

Содержание 5ROR Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5ROR Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight BLADES NOT INCLUDED ...

Страница 2: ... or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before s...

Страница 3: ...et 8 Insert downrod into yoke on top of the Fan Body Align the hole in the Downrod with the hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on the other side Install the Keeper Pin 17 Check the motor for plastic shipping stabilizers and remove if present 11 Loosen 3 screws with key hole slots and remove the 1 screw without key slot Save screw removed Remove low...

Страница 4: ...lace upper housing over downrod 19 Install ball on downrod replace cross pin and tighen screw securely 21 Hang assembled fan from the mounting brack et installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion ...

Страница 5: ...ow Replace screw removed and tighten all screws securely 33 Loosen 4 screws with key hole slots and remove 1 screw without key slot Save screw removed 32 Loosen 3 screws with key hole slots and remove 1 screw without key slot Save screw removed 34 Place switch housing with key hole slots over 3 screws and twist direc tion of arrow Replace screw removed and tighten all screws securely 36 Connect fa...

Страница 6: ...To turn the fan off press the Fan on off button To dim upper lights press and hold U L botton To dim Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Fan speed control but tons Fan on off Light dim mer for up and down lights Fan reverse button 45 ...

Страница 7: ...t a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades ...

Отзывы: