Lift Canopy to ceiling aligning the key hole slots

with the screws on the bottom of the Mounting

bracket.  Rotate the canopy Counter Clockwise

to lock in place.  Tighten the screws to secure

the Canopy.  See inset for Keyhole shape

29

Attach blades to blade arms with

screws and washers supplied. Repeat

for all 5 blades.

30

Re-install safety bar removed in step

3 by placing safety bar on screws,

sliding into place, and tightening the

2 screws.

23

Make wire connections to power source using

wire nuts provided.  Make sure that no filiments

are outside of the wire nut. After making the

wire connections, the wires should be spread

apart with the grounded conductor and the

equipment-grounding conductor on one side of

the outlet box and ungrounded conductor on

the other side of the outlet box.

28

Set dip switches on the Remote Transmitter and Remote

Receiver to the same settings.  This must be done so the

units will communcate properly.  If you have other fans you

can set to control from one transmitter by setting both

receivers the same as the transmitter.  If you have more

than one fan with remote.  You can set the dip switches to

different positiosns to have seperate control.

Remote Transmitter Dip swtiches

Remote Receiver Dip switches

24

Place canopy over downrod.

20

Place upper housing over downrod.

19

Install ball on downrod, replace cross

pin and tighen screw securely.

21

Hang assembled fan from the mounting brack-

et installed to ceiling in previous step.  Make

sure the fan is hanging straight.  Rotate fan

until the tab on the Mounting bracket engages

the slot on the Downrod Ball.  This must be

done to prevent the fan body from rotating

when the blades are in motion.

22

Fan and light kit combinations over 70 lbs,

in both flush and downrod mode the safety

cable must be installed into the house struc-

ture beams using the 3” lag screws,washers,

and lock washers. provided.  Make sure that

when the safety cable is fully extended the

lead wires are longer than the cable and no

stress is placed on the lead wires. 

25

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Install remote receiver by sliding into

opening in the Mounting bracket.  Make

sure that the dip switches on the

Transmitter and the Receiver are set to

the same position.  

26

white

black

Make wiring connections as indicated above.

White from fan to white from remote marked

N. Orange from fan to Orange from remote

marked Light/up. Blue from fan to blue from

remote marked down light. Black from fan to

Black from remote marked L. White from

house to white from remote marked AC N .

Black from house to Black from remote

marked AC L. Connect all green ground wires

to Ground wire from House.

orange

blue

Green

white

black

House

Fan

27

fuses

Содержание 5ROR Series

Страница 1: ...Quality Ceiling fans Owner s Manual Ceiling Fan Installation Instructions For 5ROR Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight BLADES NOT INCLUDED ...

Страница 2: ... or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before s...

Страница 3: ...et 8 Insert downrod into yoke on top of the Fan Body Align the hole in the Downrod with the hole in the Yoke Insert the Pin through the Yoke and Downrod until the point appears on the other side Install the Keeper Pin 17 Check the motor for plastic shipping stabilizers and remove if present 11 Loosen 3 screws with key hole slots and remove the 1 screw without key slot Save screw removed Remove low...

Страница 4: ...lace upper housing over downrod 19 Install ball on downrod replace cross pin and tighen screw securely 21 Hang assembled fan from the mounting brack et installed to ceiling in previous step Make sure the fan is hanging straight Rotate fan until the tab on the Mounting bracket engages the slot on the Downrod Ball This must be done to prevent the fan body from rotating when the blades are in motion ...

Страница 5: ...ow Replace screw removed and tighten all screws securely 33 Loosen 4 screws with key hole slots and remove 1 screw without key slot Save screw removed 32 Loosen 3 screws with key hole slots and remove 1 screw without key slot Save screw removed 34 Place switch housing with key hole slots over 3 screws and twist direc tion of arrow Replace screw removed and tighten all screws securely 36 Connect fa...

Страница 6: ...To turn the fan off press the Fan on off button To dim upper lights press and hold U L botton To dim Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked REV to reverse the rotation direction of the fan blades Fan speed control but tons Fan on off Light dim mer for up and down lights Fan reverse button 45 ...

Страница 7: ...t a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades ...

Отзывы: