Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is
properly installed to the house structure.  To reduce
the risk of fire, electric shock, or personal injury,
mount to outlet box or supporting system acceptable
for fan support. (Mounting must support at least 35
lbs.)

Use metal outlet box suitable for fan support
(must support 35 lbs). Before attaching fan to
outlet box, ensure the outlet box is securley fas-
tened by at least two points to a structural ceil-
ing member ( a loose box will cause the fan to
wabble).  

Use only the screws provided with

the outlet box.  

3

2

1

Loosen the 2 set screws in yoke for downrod to
slip into yoke. Insert downrod into yoke on top
of the Fan Body.  Align the hole in the Downrod
with the hole in the Yoke. Insert the Pin through
the Yoke and Downrod until the point appears
on the other side.  Install the Keeper Pin

Tighten the 2 Set screws on the Yoke

once the downrod is in place. Check

motor for shipping stabilizers and re-

move if present.

Tread leadwires and safety cable first

through the canopy disk, Canopy and

lastly downrod.

5

6

4

Canopy disk

Downrod

Canopy

Yoke

Cross Pin

Keeper 

Pin

Hang assembled fan from the mounting bracket in-
stalled to ceiling in previous step.  Make sure the fan
is hanging straight.  Rotate fan until the tab on the
Mounting bracket engages the slot on the Downrod
Ball.  This must be done to prevent the fan body from
rotating when the blades are in motion.

7

Make sure the studs protruding from the

bottom of the Mounting bracket are in-

stalled with threads all the way through

the bracket.  

9

For Canadian installation and for USA fan and light

kit combinations over 35 lbs, in both flush and

downrod modes the safety cable must be installed

into the house structure beams using 3” lag

screws, washers and lock washers provided. Make

sure that when the safety cable is fully extended

the lead wires are longer than the cable and no

stress is placed on the lead wires.

Note

:If Installing The Secondary Support Safety

Cable in the U.S., Do Not Remove Knockouts In

The Outlet Box.  

8

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Содержание 5HM52 ND Series

Страница 1: ...s card and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5HM52XXND Series Fan Total fan weight with light kit UL Model No AC 552 7 8 kgs 17 16 lbs ...

Страница 2: ... If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign o...

Страница 3: ... appears on the other side Install the Keeper Pin Tighten the 2 Set screws on the Yoke once the downrod is in place Check motor for shipping stabilizers and re move if present Tread leadwires and safety cable first through the canopy disk Canopy and lastly downrod 5 6 4 Canopy disk Downrod Canopy Yoke Cross Pin Keeper Pin Hang assembled fan from the mounting bracket in stalled to ceiling in previo...

Страница 4: ...knurled nuts securely The canopy should adjust for any irregularity in the ceiling or Outlet box 13 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from Fan to White Neutral wire from house Connect Ground leads from mounting bracket and downrod to Ground lead from house Refer to Safety Tips section of manual 10 Cover Ring House Fan Blue Black White Green Bla...

Страница 5: ...using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 23 Connect black and blue wire from fan to Black or Hot wire from house Connect White wire from...

Страница 6: ...e lights by turning off the wall switch breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on 31 Locate blue and white wire from the fan marked For light kit Connect blue from fan to black from light and white from fan to white from light by pushing connectors together 32 Attach switch cap to fan by lining up 2 slot ear holes and 1 screw hole and twisting cap Then tig...

Страница 7: ... 2013 Monte Carlo Fan Company 11 15 2013 7 Align hole in glass and hole in finial cap to allow the fan speed pull chain to pass through Install finial nut and tighten 36 ...

Страница 8: ...bove the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not sup plied between the blade and blade holder at the screw closest t...

Страница 9: ...Jan 2012 new fornmat Jul 2013 Update for CUL regulation Nov 2013 5HM52XXND ...

Отзывы: