background image

7/1/2013

© 2013 Monte Carlo Fan Company

4

10

Install keeper pin.

11

Tighten the 2 set screws on 

the yoke, once the down rod 

is in place.

12

Loosen one and remove one 

preassembled screws from 

m o u n t i n g   b ra c k e t .   S a v e 

screw for later use.   

13

Hang assembled fan from the mounting 

bracket installed to ceiling in previous 

step. Make sure the fan is hanging 

straight. Rotate fan until the tab on the 

Mounting bracket engages the slot on 

the Downrod Ball. This must be done to 

prevent the fan body from rotating when 

the blades are in motion.

15

Connect black and blue wire from fan to 

Black or (Hot) wire from house.  Connect 

White wire from Fan to White (Neutral) 

wire from house.  Connect Ground leads 

from mounting bracket and downrod 

to Ground lead from house.  Refer to 

Safety Tips section of manual.

16

Make wire connections to power source 

using wire nuts provided.  Make sure that 

no  filiments  are  outside  of  the  wirenut.  After 

making the wire connections, the wires should 

be spread apart with the grounded conductor 

and the equipment-grounding conductor on 

one side of the outlet box and ungrounded 

conductor on the other side of the outlet box. 

The splices after being made should be turned 

upward and pushed carefully up into the outlet 

box. 

17

18

Lift canopy up, aligning its keyhole 

slot with the preassembled screw 

on mounting bracket and twist till 

lock. Install the screw removed 

in step 12. Tighten all screws 

securely. 

Attached canopy bottom cap 

onto canopy by aligning its 

notches with the screws on 

mounting bracket and twist 

clockwise till tight. 

Supply

circuit

For Canadian installation and for USA fan and light 

kit combinations over 35 lbs, in both flush and 

downrod mode the safety cable must be installed 

into the house structure beams using the 3” lag 

screws,washers, and lock washers. provided.  Make 

sure that when the safety cable is fully extended 

the leadwires are longer than the cable and no 

stress is placed on the leadwires.

Note

: If Installing The Secondary Support Safety 

Cable in the U.S., Do Not Remove Knockouts In The 

Outlet Box. 

14

Lag screw

Safety cable

Washer

Lock washer

Lag screw

Safety cable

Safety cable installation

Содержание 5CU52 Series

Страница 1: ...Model No AC AC 303OD Total fan weight DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture pleas...

Страница 2: ...ockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of p...

Страница 3: ...d with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the...

Страница 4: ...apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should...

Страница 5: ...harness from motor Attached switch housing on to the plate on motor aligning the keyhole slots with the preassembled screws on the plate Twist clockwise till lock Install the screw removed in step 22...

Страница 6: ...7 1 2013 2013 Monte Carlo Fan Company 6 28 Install switch housing cover with the screws removed in step 26...

Страница 7: ...d of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Ma...

Страница 8: ...Mar 2012 new format Jul 2013 Update for CUL regulation...

Отзывы: