1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION

: Make sure main power is turned off.

way. Fan will not operate when switch is in the middle.

4.If this fan uses remote controller, make sure dip switches are setting properly and make sure 

battery is effective. 

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other 

or against the interior wall of the switch housing.

CAUTION

:  Make sure main power is turned off before entering switch housing.

4.Check to be sure light bulb is tight in socket and not touching the glass shade.

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear 

after this period.

1.If this is a downrod mount fan, make sure the ridge on mounting bracket engages the notch in 

the downrod ball.

2.Make sure that canopy, mounting bracket or mounting plate are tightened securely to ceiling 

4.Check that all blade holders are tightened securely to motor.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by 

selecting a point on the ceiling above the tip of one of the blades. Measure this distance from 

blade tip to ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned 

for measurement. Repeat for each blade. If all blade levels are not equal, you can adjust blade 

levels by the following procedure. To adjust a blade tip down, insert a washer (not supplied) 

between the blade and blade holder at the screw closest to the motor. To adjust a blade tip up, 

insert washer (not supplied) between the blade and blade holder at the two screws farthest from 

the motor. Reverse the position of the washer if blades mount from top of blade.

6.If  blade  wobble  is  still  noticeable,  interchanging  two  adjacent  (side  by  side)  blades  can 

redistribute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulb and make sure bulb is tight in socket.

5.Remove light kit and check the plug connections if they are present.

6.If this fan uses remote controller, make sure dip switches are setting properly and make sure 

battery is effective. 

 

CAUTION

: Make sure main power is turned off before entering switch housing and/or canopy.

WARNING

: Over lamping the fan will result in the fan lights shutting down until the proper 

wattage of bulbs are installed. Reset the lights by turning off, replace bulbs with the correct 

wattage bulbs, Turn power on.

                                       

                               

2. If fan sounds noisy:

3. If fan wobbles:

4. If light does not work:

1. If fan does not start:

Trouble

Suggested Remedy

Содержание 5CQM52XX-L Series

Страница 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Страница 2: ...he Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building s...

Страница 3: ...en the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Fig 1 Before installing this fan make sure the outlet box is properly installed...

Страница 4: ...her side and insert keeper pin on cross pin Pull the downrod up tight against the cross pin and then evenly tighten the downrod set screws on motor housing yoke Fig 3 Warning Cross pin and keeper pin...

Страница 5: ...canopy over the mounting bracket hook Use one of non slotted holes on the rim of the canopy Fig 5 2 Safety Cable Installation For Canadian installation and for USA fan and light kit combinations over...

Страница 6: ...Installation Partially loosen 2 of the set screws on mounting bracket corresponding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Raise canopy to mounting br...

Страница 7: ...y to motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Fig 9 Note Tighten blade bracket screws twice a year Switch housing installation and...

Страница 8: ...ke sure that canopy mounting bracket or mounting plate are tightened securely to ceiling 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade...

Страница 9: ...Apr 2015...

Отзывы: